SM910021

展开表
1/5
IDNR
IDNR
Short Description
DESCSHORT
Long Description
DESCLONG
Product ID of the Manufacturer
MANUID
Delivery Time
DELTIME
Display
ARDTEEL_ANZEIGE
Type of switching function
ARDTEEL_AUSFUEHRUNGDERSCHALTFUNKTION
Type of analog output
ARDTEEL_AUSFUEHRUNGDESANALOGAUSGANGS
1
2
3
4
5
6
7
8
9
10
11
SM950021
Sensor flow, water, magnetic-inductive, 134x80x80mm, G 2", 19-30V diagnostic coverage, push/pull programmable/configurable, 0/2-10V / 0/4-20mA, M12 plug-in connector 4-pin, stainless steel 1.4404, pressure resistance 16bar, 3-650l/min
If an electrically conductive liquid moves across a magnetic field, a voltage is generated perpendicular to this magnetic field that is dependent on the flow velocity. This voltage is measured by electrodes located in the wall of the measuring tube. Microcontrollers evaluate this voltage, calculate the flow rate and show it on the display. An analog signal and a transistor switching output are available for further processing.
SM950021
28
TFT display
Programmable/configurable
0 - 10V
SM920021
Flow sensor, water, magnetic-inductive, 72x68x68mm, G 1", 19-30V DC, push/pull programmable/configurable, 0/2-10V / 0/4-20mA, M12-connector 4pin, stainless steel 1.4404, pressure resistance 16bar, 0,4-100l/min
If an electrically conductive liquid moves across a magnetic field, a voltage is generated perpendicular to this magnetic field that is dependent on the flow velocity. This voltage is measured by electrodes located in the wall of the measuring tube. Microcontrollers evaluate this voltage, calculate the flow rate and show it on the display. An analog signal and a transistor switching output are available for further processing.
SM920021
28
TFT display
Programmable/configurable
0 - 10V
SM910020
Flow sensor, water, magnetic-inductive, 72x68x68mm, G 3/4", 19-30V DC, push/pull programmable/configurable, 0/2-10V / 0/4-20mA, M12-connector 4pin, stainless steel 1.4404, pressure resistance 16bar, 0,1-25l/min
If an electrically conductive liquid moves across a magnetic field, a voltage is generated perpendicular to this magnetic field that is dependent on the flow velocity. This voltage is measured by electrodes located in the wall of the measuring tube. Microcontrollers evaluate this voltage, calculate the flow rate and show it on the display. An analog signal and a transistor switching output are available for further processing.
SM910020
28
TFT display
Programmable/configurable
0 - 10V
SM920020
Flow sensor, water, magnetic-inductive, 72x68x68mm, G 1", 19-30V DC, push/pull programmable/configurable, 0/2-10V / 0/4-20mA, M12-connector 4pin, stainless steel 1.4404, pressure resistance 16bar, 0,2-50l/min
If an electrically conductive liquid moves across a magnetic field, a voltage is generated perpendicular to this magnetic field that is dependent on the flow velocity. This voltage is measured by electrodes located in the wall of the measuring tube. Microcontrollers evaluate this voltage, calculate the flow rate and show it on the display. An analog signal and a transistor switching output are available for further processing.
SM920020
28
TFT display
Programmable/configurable
0 - 10V
SM910021
Flow sensor, water, magnetic-inductive, 72x68x68mm, G 3/4", 19-30V DC, push/pull programmable/configurable, 0/2-10V / 0/4-20mA, M12-connector 4pin, stainless steel 1.4404, pressure resistance 16bar, 0,2-50l/min
If an electrically conductive liquid moves across a magnetic field, a voltage is generated perpendicular to this magnetic field that is dependent on the flow velocity. This voltage is measured by electrodes located in the wall of the measuring tube. Microcontrollers evaluate this voltage, calculate the flow rate and show it on the display. An analog signal and a transistor switching output are available for further processing.
SM910021
28
TFT display
Programmable/configurable
0 - 10V
SM900021
Flow sensor, water, magnetic-inductive, 72x68x68mm, G 1/2", 19-30V DC, push/pull programmable/configurable, 0/2-10V / 0/4-20mA, M12-connector 4pin, stainless steel 1.4404, pressure resistance 16bar, 0,04-10l/min
If an electrically conductive liquid moves across a magnetic field, a voltage is generated perpendicular to this magnetic field that is dependent on the flow velocity. This voltage is measured by electrodes located in the wall of the measuring tube. Microcontrollers evaluate this voltage, calculate the flow rate and show it on the display. An analog signal and a transistor switching output are available for further processing.
SM900021
28
TFT display
Programmable/configurable
0 - 10V
SM920023
Sensor flow, water, magnetic-inductive, 72x68x68mm, G 1", 19-30V DC, push/pull programmable/configurable, 0/2-10V / 0/4-20mA, M12 connector 4pin, stainless steel 1.4404, pressure resistance 16bar, 0,4-100l/min, EPDM
If an electrically conductive liquid moves across a magnetic field, a voltage is generated perpendicular to this magnetic field that is dependent on the flow velocity. This voltage is measured by electrodes located in the wall of the measuring tube. Microcontrollers evaluate this voltage, calculate the flow rate and show it on the display. An analog signal and a transistor switching output are available for further processing.
SM920023
28
TFT display
Programmable/configurable
0 - 10V
SM950020
Sensor flow, water, magnetic-inductive, 134x80x80mm, G 2", 19-30V DC, push/pull programmable/configurable, 0/2-10V / 0/4-20mA, M12 connector 4pin, stainless steel 1.4404, pressure resistance 16bar, 1,5-350l/min
If an electrically conductive liquid moves across a magnetic field, a voltage is generated perpendicular to this magnetic field that is dependent on the flow velocity. This voltage is measured by electrodes located in the wall of the measuring tube. Microcontrollers evaluate this voltage, calculate the flow rate and show it on the display. An analog signal and a transistor switching output are available for further processing.
SM950020
28
TFT display
Programmable/configurable
0 - 10V
SM95F001
Sensor flow, water, magnetic-inductive, 134x80x80mm, G 2", 19-30V DC, push/pull programmable/configurable, 0/2-10V / 0/4-20mA, M12 connector 4pin, stainless steel 1.4404, pressure-proof 16bar, 1,5-350l/min, separated version, -20 - 140°C
If an electrically conductive liquid moves across a magnetic field, a voltage is generated perpendicular to this magnetic field that is dependent on the flow velocity. This voltage is measured by electrodes located in the wall of the measuring tube. Microcontrollers evaluate this voltage, calculate the flow rate and show it on the display. An analog signal and a transistor switching output are available for further processing.
SM95F001
35
TFT display
Programmable/configurable
0 - 10V
SM890020
Flow sensor, water, magnetic-inductive, 72x68x68mm, G 1/4", 19-30V DC, push/pull programmable/configurable, 0/2-10V / 0/4-20mA, M12-connector 4pole, stainless steel 1.4404, pressure resistance 16bar, 0,01-1l/min
If an electrically conductive liquid moves across a magnetic field, a voltage is generated perpendicular to this magnetic field that is dependent on the flow velocity. This voltage is measured by electrodes located in the wall of the measuring tube. Microcontrollers evaluate this voltage, calculate the flow rate and show it on the display. An analog signal and a transistor switching output are available for further processing.
SM890020
28
TFT display
Programmable/configurable
0 - 10V
SM900020
Flow sensor, water, magnetic-inductive, 72x68x68mm, G 1/2", 19-30V DC, push/pull programmable/configurable, 0/2-10V / 0/4-20mA, M12-connector 4pin, stainless steel 1.4404, pressure resistance 16bar, 0,03-3l/min
If an electrically conductive liquid moves across a magnetic field, a voltage is generated perpendicular to this magnetic field that is dependent on the flow velocity. This voltage is measured by electrodes located in the wall of the measuring tube. Microcontrollers evaluate this voltage, calculate the flow rate and show it on the display. An analog signal and a transistor switching output are available for further processing.
SM900020