2540253_W-CTRL-CC-WP-2x61,0A-T4-DOL-WM-PKG

展开表
1/5
Article number
ARTICLE_ID
Type code
ARTICLE_NAME
LOD Level
LOD
Manufacturer
MANUFACTURER_NAME
Short text
DESCRIPTION_SHORT
Tender text
DESCRIPTION_LONG
Mounting method
EF000003
Type of covering
EF000339
Type of door
EF004464
Type of door position
POS
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
2540243
W-CTRL-CC-WP-2x20,0A-T4-DOL-WM-PKG
350
WILO SE
Comfort control system for all conventional pumps in glandless and glanded design with fixed speeds and three-phase motors.
Wilo-Comfort Controller for connecting pumps for water supply from bore holes and tanks. Fully electronic Comfort Controller (CC) in steel sheet housing as floor model or for wall fixation, RAL 7035 (structure), protection class IP54, completely wired. Switchgear suitable for connection to three-phase networks 3/PE 400 V/50 Hz in accordance with IEC 60038 (other voltages on request). Specially adjusted for borehole pumps from the Wilo catalogue. The Comfort Controller CC consists of: *Internal power supply *CPU (+ backup battery) *Analogue/digital modules *Power section with fuses, contactors and motor-protection equipment *Graphics-capable touch display with 3-colour backlight for indicating the operating status operation/fault/acknowledged fault, and supporting symbols and plain text for menu navigation in up to 27 languages, with European and Asiatic characters *3 user levels, display and selection of menu language, passwords, operating parameters, elapsed time indicator (individual and total operating hours), history memory for operating and error messages with time stamp via real time clock, pump status and control variable actual value display, diagram function *Main switch, internal Manual-0-Automatic service selector on each pump *Operating mode selection (Manual/Off/Automatic) for each pump via touch display *Potential-free contacts (changeover contact) for collective run and fault signals (SBM/SSM), individual operation and individual fault signals (EBM/ESM) and dry running signal for each pump *Evaluation relay (for each pump) for the connection of submersible electrodes for low-water cut-out switchgear (detachable for each pump with separated boreholes) *Digital inputs for switching external systems ON/OFF*, anti-frost protection alarm signal*, setpoint switchover** *Analogue input 0/4-20mA for external setpoint adjustment *Overload protection via thermal winding contact, motor protection via motor protection switch/in star-delta start-up, starting from 5.5 kW via thermal overload relay (optional: PTC/PT100 triggering available) *PID controller, automatic pump alteration and service life optimisation for multi-pump systems *Three setpoints are selectable by default *Automatic fault-actuated switchover to idle pump *Short test run of pump(s) during standstill, pilot pump function *Automatic, load-sensitive cut-in of peak-load pump depending on the programmable control variables Programmable control variables: *Pressure - constant, p-c *Differential pressure - constant, dp-c Option for live-zero evaluation for conductivity test (sensor/setpoint input), select from: *Signal and all drives full load *Signal and system deactivation *Signal and one pump at speed adjustable on frequency converter Additional charge for optional modules (installation in factory or later after technical clarification): *Temperature module *For connection to BMS systems in accordance with VDI 3814, via analogue/GSM modem, web server *For connection to bus systems: Modbus RTU, Profibus, LON bus, CAN bus, Ethernet, others on request. *Signal converter for external remote setpoint adjustment or control mode using 0/2 – 10 V signals. *Evaluation relay for PTC/PT100. *Buffered power supply unit *Measurement of electrical parameters, such as voltage, current, effective power, power factor, etc. *<I> on-site potential-free NC contact</I> ** <I>on-site potential-free NO contact</I> Order example: W-CTRL-CC-WP-2x20,0A-T4-DOL-BM-PKG Switchgear for 2 pumps with max. rated pump current of 20.0 A WP = version for borehole pump applications (well pump), contains the equipment described above T4 = mains connection 3~400 V DOL = activation type of the pump: direct BM = designed as switch cabinet floor model PKG = with packaging Scope of delivery *Switchgear *Installation and operating instructions *Circuit diagram
Wall-mounted installation
EV004216
EV002464
0
2540244
W-CTRL-CC-WP-1x24,0A-T4-DOL-WM-PKG
350
WILO SE
Comfort control system for all conventional pumps in glandless and glanded design with fixed speeds and three-phase motors.
Wilo-Comfort Controller for connecting pumps for water supply from bore holes and tanks. Fully electronic Comfort Controller (CC) in steel sheet housing as floor model or for wall fixation, RAL 7035 (structure), protection class IP54, completely wired. Switchgear suitable for connection to three-phase networks 3/PE 400 V/50 Hz in accordance with IEC 60038 (other voltages on request). Specially adjusted for borehole pumps from the Wilo catalogue. The Comfort Controller CC consists of: *Internal power supply *CPU (+ backup battery) *Analogue/digital modules *Power section with fuses, contactors and motor-protection equipment *Graphics-capable touch display with 3-colour backlight for indicating the operating status operation/fault/acknowledged fault, and supporting symbols and plain text for menu navigation in up to 27 languages, with European and Asiatic characters *3 user levels, display and selection of menu language, passwords, operating parameters, elapsed time indicator (individual and total operating hours), history memory for operating and error messages with time stamp via real time clock, pump status and control variable actual value display, diagram function *Main switch, internal Manual-0-Automatic service selector on each pump *Operating mode selection (Manual/Off/Automatic) for each pump via touch display *Potential-free contacts (changeover contact) for collective run and fault signals (SBM/SSM), individual operation and individual fault signals (EBM/ESM) and dry running signal for each pump *Evaluation relay (for each pump) for the connection of submersible electrodes for low-water cut-out switchgear (detachable for each pump with separated boreholes) *Digital inputs for switching external systems ON/OFF*, anti-frost protection alarm signal*, setpoint switchover** *Analogue input 0/4-20mA for external setpoint adjustment *Overload protection via thermal winding contact, motor protection via motor protection switch/in star-delta start-up, starting from 5.5 kW via thermal overload relay (optional: PTC/PT100 triggering available) *PID controller, automatic pump alteration and service life optimisation for multi-pump systems *Three setpoints are selectable by default *Automatic fault-actuated switchover to idle pump *Short test run of pump(s) during standstill, pilot pump function *Automatic, load-sensitive cut-in of peak-load pump depending on the programmable control variables Programmable control variables: *Pressure - constant, p-c *Differential pressure - constant, dp-c Option for live-zero evaluation for conductivity test (sensor/setpoint input), select from: *Signal and all drives full load *Signal and system deactivation *Signal and one pump at speed adjustable on frequency converter Additional charge for optional modules (installation in factory or later after technical clarification): *Temperature module *For connection to BMS systems in accordance with VDI 3814, via analogue/GSM modem, web server *For connection to bus systems: Modbus RTU, Profibus, LON bus, CAN bus, Ethernet, others on request. *Signal converter for external remote setpoint adjustment or control mode using 0/2 – 10 V signals. *Evaluation relay for PTC/PT100. *Buffered power supply unit *Measurement of electrical parameters, such as voltage, current, effective power, power factor, etc. *<I> on-site potential-free NC contact</I> ** <I>on-site potential-free NO contact</I> Order example: W-CTRL-CC-WP-2x20,0A-T4-DOL-BM-PKG Switchgear for 2 pumps with max. rated pump current of 20.0 A WP = version for borehole pump applications (well pump), contains the equipment described above T4 = mains connection 3~400 V DOL = activation type of the pump: direct BM = designed as switch cabinet floor model PKG = with packaging Scope of delivery *Switchgear *Installation and operating instructions *Circuit diagram
Wall-mounted installation
EV004216
EV002464
0
2540245
W-CTRL-CC-WP-2x24,0A-T4-DOL-WM-PKG
350
WILO SE
Comfort control system for all conventional pumps in glandless and glanded design with fixed speeds and three-phase motors.
Wilo-Comfort Controller for connecting pumps for water supply from bore holes and tanks. Fully electronic Comfort Controller (CC) in steel sheet housing as floor model or for wall fixation, RAL 7035 (structure), protection class IP54, completely wired. Switchgear suitable for connection to three-phase networks 3/PE 400 V/50 Hz in accordance with IEC 60038 (other voltages on request). Specially adjusted for borehole pumps from the Wilo catalogue. The Comfort Controller CC consists of: *Internal power supply *CPU (+ backup battery) *Analogue/digital modules *Power section with fuses, contactors and motor-protection equipment *Graphics-capable touch display with 3-colour backlight for indicating the operating status operation/fault/acknowledged fault, and supporting symbols and plain text for menu navigation in up to 27 languages, with European and Asiatic characters *3 user levels, display and selection of menu language, passwords, operating parameters, elapsed time indicator (individual and total operating hours), history memory for operating and error messages with time stamp via real time clock, pump status and control variable actual value display, diagram function *Main switch, internal Manual-0-Automatic service selector on each pump *Operating mode selection (Manual/Off/Automatic) for each pump via touch display *Potential-free contacts (changeover contact) for collective run and fault signals (SBM/SSM), individual operation and individual fault signals (EBM/ESM) and dry running signal for each pump *Evaluation relay (for each pump) for the connection of submersible electrodes for low-water cut-out switchgear (detachable for each pump with separated boreholes) *Digital inputs for switching external systems ON/OFF*, anti-frost protection alarm signal*, setpoint switchover** *Analogue input 0/4-20mA for external setpoint adjustment *Overload protection via thermal winding contact, motor protection via motor protection switch/in star-delta start-up, starting from 5.5 kW via thermal overload relay (optional: PTC/PT100 triggering available) *PID controller, automatic pump alteration and service life optimisation for multi-pump systems *Three setpoints are selectable by default *Automatic fault-actuated switchover to idle pump *Short test run of pump(s) during standstill, pilot pump function *Automatic, load-sensitive cut-in of peak-load pump depending on the programmable control variables Programmable control variables: *Pressure - constant, p-c *Differential pressure - constant, dp-c Option for live-zero evaluation for conductivity test (sensor/setpoint input), select from: *Signal and all drives full load *Signal and system deactivation *Signal and one pump at speed adjustable on frequency converter Additional charge for optional modules (installation in factory or later after technical clarification): *Temperature module *For connection to BMS systems in accordance with VDI 3814, via analogue/GSM modem, web server *For connection to bus systems: Modbus RTU, Profibus, LON bus, CAN bus, Ethernet, others on request. *Signal converter for external remote setpoint adjustment or control mode using 0/2 – 10 V signals. *Evaluation relay for PTC/PT100. *Buffered power supply unit *Measurement of electrical parameters, such as voltage, current, effective power, power factor, etc. *<I> on-site potential-free NC contact</I> ** <I>on-site potential-free NO contact</I> Order example: W-CTRL-CC-WP-2x20,0A-T4-DOL-BM-PKG Switchgear for 2 pumps with max. rated pump current of 20.0 A WP = version for borehole pump applications (well pump), contains the equipment described above T4 = mains connection 3~400 V DOL = activation type of the pump: direct BM = designed as switch cabinet floor model PKG = with packaging Scope of delivery *Switchgear *Installation and operating instructions *Circuit diagram
Wall-mounted installation
EV004216
EV002464
0
2540246
W-CTRL-CC-WP-1x32,0A-T4-DOL-WM-PKG
350
WILO SE
Comfort control system for all conventional pumps in glandless and glanded design with fixed speeds and three-phase motors.
Wilo-Comfort Controller for connecting pumps for water supply from bore holes and tanks. Fully electronic Comfort Controller (CC) in steel sheet housing as floor model or for wall fixation, RAL 7035 (structure), protection class IP54, completely wired. Switchgear suitable for connection to three-phase networks 3/PE 400 V/50 Hz in accordance with IEC 60038 (other voltages on request). Specially adjusted for borehole pumps from the Wilo catalogue. The Comfort Controller CC consists of: *Internal power supply *CPU (+ backup battery) *Analogue/digital modules *Power section with fuses, contactors and motor-protection equipment *Graphics-capable touch display with 3-colour backlight for indicating the operating status operation/fault/acknowledged fault, and supporting symbols and plain text for menu navigation in up to 27 languages, with European and Asiatic characters *3 user levels, display and selection of menu language, passwords, operating parameters, elapsed time indicator (individual and total operating hours), history memory for operating and error messages with time stamp via real time clock, pump status and control variable actual value display, diagram function *Main switch, internal Manual-0-Automatic service selector on each pump *Operating mode selection (Manual/Off/Automatic) for each pump via touch display *Potential-free contacts (changeover contact) for collective run and fault signals (SBM/SSM), individual operation and individual fault signals (EBM/ESM) and dry running signal for each pump *Evaluation relay (for each pump) for the connection of submersible electrodes for low-water cut-out switchgear (detachable for each pump with separated boreholes) *Digital inputs for switching external systems ON/OFF*, anti-frost protection alarm signal*, setpoint switchover** *Analogue input 0/4-20mA for external setpoint adjustment *Overload protection via thermal winding contact, motor protection via motor protection switch/in star-delta start-up, starting from 5.5 kW via thermal overload relay (optional: PTC/PT100 triggering available) *PID controller, automatic pump alteration and service life optimisation for multi-pump systems *Three setpoints are selectable by default *Automatic fault-actuated switchover to idle pump *Short test run of pump(s) during standstill, pilot pump function *Automatic, load-sensitive cut-in of peak-load pump depending on the programmable control variables Programmable control variables: *Pressure - constant, p-c *Differential pressure - constant, dp-c Option for live-zero evaluation for conductivity test (sensor/setpoint input), select from: *Signal and all drives full load *Signal and system deactivation *Signal and one pump at speed adjustable on frequency converter Additional charge for optional modules (installation in factory or later after technical clarification): *Temperature module *For connection to BMS systems in accordance with VDI 3814, via analogue/GSM modem, web server *For connection to bus systems: Modbus RTU, Profibus, LON bus, CAN bus, Ethernet, others on request. *Signal converter for external remote setpoint adjustment or control mode using 0/2 – 10 V signals. *Evaluation relay for PTC/PT100. *Buffered power supply unit *Measurement of electrical parameters, such as voltage, current, effective power, power factor, etc. *<I> on-site potential-free NC contact</I> ** <I>on-site potential-free NO contact</I> Order example: W-CTRL-CC-WP-2x20,0A-T4-DOL-BM-PKG Switchgear for 2 pumps with max. rated pump current of 20.0 A WP = version for borehole pump applications (well pump), contains the equipment described above T4 = mains connection 3~400 V DOL = activation type of the pump: direct BM = designed as switch cabinet floor model PKG = with packaging Scope of delivery *Switchgear *Installation and operating instructions *Circuit diagram
Wall-mounted installation
EV004216
EV002464
0
2540247
W-CTRL-CC-WP-2x32,0A-T4-DOL-WM-PKG
350
WILO SE
Comfort control system for all conventional pumps in glandless and glanded design with fixed speeds and three-phase motors.
Wilo-Comfort Controller for connecting pumps for water supply from bore holes and tanks. Fully electronic Comfort Controller (CC) in steel sheet housing as floor model or for wall fixation, RAL 7035 (structure), protection class IP54, completely wired. Switchgear suitable for connection to three-phase networks 3/PE 400 V/50 Hz in accordance with IEC 60038 (other voltages on request). Specially adjusted for borehole pumps from the Wilo catalogue. The Comfort Controller CC consists of: *Internal power supply *CPU (+ backup battery) *Analogue/digital modules *Power section with fuses, contactors and motor-protection equipment *Graphics-capable touch display with 3-colour backlight for indicating the operating status operation/fault/acknowledged fault, and supporting symbols and plain text for menu navigation in up to 27 languages, with European and Asiatic characters *3 user levels, display and selection of menu language, passwords, operating parameters, elapsed time indicator (individual and total operating hours), history memory for operating and error messages with time stamp via real time clock, pump status and control variable actual value display, diagram function *Main switch, internal Manual-0-Automatic service selector on each pump *Operating mode selection (Manual/Off/Automatic) for each pump via touch display *Potential-free contacts (changeover contact) for collective run and fault signals (SBM/SSM), individual operation and individual fault signals (EBM/ESM) and dry running signal for each pump *Evaluation relay (for each pump) for the connection of submersible electrodes for low-water cut-out switchgear (detachable for each pump with separated boreholes) *Digital inputs for switching external systems ON/OFF*, anti-frost protection alarm signal*, setpoint switchover** *Analogue input 0/4-20mA for external setpoint adjustment *Overload protection via thermal winding contact, motor protection via motor protection switch/in star-delta start-up, starting from 5.5 kW via thermal overload relay (optional: PTC/PT100 triggering available) *PID controller, automatic pump alteration and service life optimisation for multi-pump systems *Three setpoints are selectable by default *Automatic fault-actuated switchover to idle pump *Short test run of pump(s) during standstill, pilot pump function *Automatic, load-sensitive cut-in of peak-load pump depending on the programmable control variables Programmable control variables: *Pressure - constant, p-c *Differential pressure - constant, dp-c Option for live-zero evaluation for conductivity test (sensor/setpoint input), select from: *Signal and all drives full load *Signal and system deactivation *Signal and one pump at speed adjustable on frequency converter Additional charge for optional modules (installation in factory or later after technical clarification): *Temperature module *For connection to BMS systems in accordance with VDI 3814, via analogue/GSM modem, web server *For connection to bus systems: Modbus RTU, Profibus, LON bus, CAN bus, Ethernet, others on request. *Signal converter for external remote setpoint adjustment or control mode using 0/2 – 10 V signals. *Evaluation relay for PTC/PT100. *Buffered power supply unit *Measurement of electrical parameters, such as voltage, current, effective power, power factor, etc. *<I> on-site potential-free NC contact</I> ** <I>on-site potential-free NO contact</I> Order example: W-CTRL-CC-WP-2x20,0A-T4-DOL-BM-PKG Switchgear for 2 pumps with max. rated pump current of 20.0 A WP = version for borehole pump applications (well pump), contains the equipment described above T4 = mains connection 3~400 V DOL = activation type of the pump: direct BM = designed as switch cabinet floor model PKG = with packaging Scope of delivery *Switchgear *Installation and operating instructions *Circuit diagram
Wall-mounted installation
EV004216
EV002464
0
2540248
W-CTRL-CC-WP-1x37,0A-T4-DOL-WM-PKG
350
WILO SE
Comfort control system for all conventional pumps in glandless and glanded design with fixed speeds and three-phase motors.
Wilo-Comfort Controller for connecting pumps for water supply from bore holes and tanks. Fully electronic Comfort Controller (CC) in steel sheet housing as floor model or for wall fixation, RAL 7035 (structure), protection class IP54, completely wired. Switchgear suitable for connection to three-phase networks 3/PE 400 V/50 Hz in accordance with IEC 60038 (other voltages on request). Specially adjusted for borehole pumps from the Wilo catalogue. The Comfort Controller CC consists of: *Internal power supply *CPU (+ backup battery) *Analogue/digital modules *Power section with fuses, contactors and motor-protection equipment *Graphics-capable touch display with 3-colour backlight for indicating the operating status operation/fault/acknowledged fault, and supporting symbols and plain text for menu navigation in up to 27 languages, with European and Asiatic characters *3 user levels, display and selection of menu language, passwords, operating parameters, elapsed time indicator (individual and total operating hours), history memory for operating and error messages with time stamp via real time clock, pump status and control variable actual value display, diagram function *Main switch, internal Manual-0-Automatic service selector on each pump *Operating mode selection (Manual/Off/Automatic) for each pump via touch display *Potential-free contacts (changeover contact) for collective run and fault signals (SBM/SSM), individual operation and individual fault signals (EBM/ESM) and dry running signal for each pump *Evaluation relay (for each pump) for the connection of submersible electrodes for low-water cut-out switchgear (detachable for each pump with separated boreholes) *Digital inputs for switching external systems ON/OFF*, anti-frost protection alarm signal*, setpoint switchover** *Analogue input 0/4-20mA for external setpoint adjustment *Overload protection via thermal winding contact, motor protection via motor protection switch/in star-delta start-up, starting from 5.5 kW via thermal overload relay (optional: PTC/PT100 triggering available) *PID controller, automatic pump alteration and service life optimisation for multi-pump systems *Three setpoints are selectable by default *Automatic fault-actuated switchover to idle pump *Short test run of pump(s) during standstill, pilot pump function *Automatic, load-sensitive cut-in of peak-load pump depending on the programmable control variables Programmable control variables: *Pressure - constant, p-c *Differential pressure - constant, dp-c Option for live-zero evaluation for conductivity test (sensor/setpoint input), select from: *Signal and all drives full load *Signal and system deactivation *Signal and one pump at speed adjustable on frequency converter Additional charge for optional modules (installation in factory or later after technical clarification): *Temperature module *For connection to BMS systems in accordance with VDI 3814, via analogue/GSM modem, web server *For connection to bus systems: Modbus RTU, Profibus, LON bus, CAN bus, Ethernet, others on request. *Signal converter for external remote setpoint adjustment or control mode using 0/2 – 10 V signals. *Evaluation relay for PTC/PT100. *Buffered power supply unit *Measurement of electrical parameters, such as voltage, current, effective power, power factor, etc. *<I> on-site potential-free NC contact</I> ** <I>on-site potential-free NO contact</I> Order example: W-CTRL-CC-WP-2x20,0A-T4-DOL-BM-PKG Switchgear for 2 pumps with max. rated pump current of 20.0 A WP = version for borehole pump applications (well pump), contains the equipment described above T4 = mains connection 3~400 V DOL = activation type of the pump: direct BM = designed as switch cabinet floor model PKG = with packaging Scope of delivery *Switchgear *Installation and operating instructions *Circuit diagram
Wall-mounted installation
EV004216
EV002464
0
2540249
W-CTRL-CC-WP-2x37,0A-T4-DOL-WM-PKG
350
WILO SE
Comfort control system for all conventional pumps in glandless and glanded design with fixed speeds and three-phase motors.
Wilo-Comfort Controller for connecting pumps for water supply from bore holes and tanks. Fully electronic Comfort Controller (CC) in steel sheet housing as floor model or for wall fixation, RAL 7035 (structure), protection class IP54, completely wired. Switchgear suitable for connection to three-phase networks 3/PE 400 V/50 Hz in accordance with IEC 60038 (other voltages on request). Specially adjusted for borehole pumps from the Wilo catalogue. The Comfort Controller CC consists of: *Internal power supply *CPU (+ backup battery) *Analogue/digital modules *Power section with fuses, contactors and motor-protection equipment *Graphics-capable touch display with 3-colour backlight for indicating the operating status operation/fault/acknowledged fault, and supporting symbols and plain text for menu navigation in up to 27 languages, with European and Asiatic characters *3 user levels, display and selection of menu language, passwords, operating parameters, elapsed time indicator (individual and total operating hours), history memory for operating and error messages with time stamp via real time clock, pump status and control variable actual value display, diagram function *Main switch, internal Manual-0-Automatic service selector on each pump *Operating mode selection (Manual/Off/Automatic) for each pump via touch display *Potential-free contacts (changeover contact) for collective run and fault signals (SBM/SSM), individual operation and individual fault signals (EBM/ESM) and dry running signal for each pump *Evaluation relay (for each pump) for the connection of submersible electrodes for low-water cut-out switchgear (detachable for each pump with separated boreholes) *Digital inputs for switching external systems ON/OFF*, anti-frost protection alarm signal*, setpoint switchover** *Analogue input 0/4-20mA for external setpoint adjustment *Overload protection via thermal winding contact, motor protection via motor protection switch/in star-delta start-up, starting from 5.5 kW via thermal overload relay (optional: PTC/PT100 triggering available) *PID controller, automatic pump alteration and service life optimisation for multi-pump systems *Three setpoints are selectable by default *Automatic fault-actuated switchover to idle pump *Short test run of pump(s) during standstill, pilot pump function *Automatic, load-sensitive cut-in of peak-load pump depending on the programmable control variables Programmable control variables: *Pressure - constant, p-c *Differential pressure - constant, dp-c Option for live-zero evaluation for conductivity test (sensor/setpoint input), select from: *Signal and all drives full load *Signal and system deactivation *Signal and one pump at speed adjustable on frequency converter Additional charge for optional modules (installation in factory or later after technical clarification): *Temperature module *For connection to BMS systems in accordance with VDI 3814, via analogue/GSM modem, web server *For connection to bus systems: Modbus RTU, Profibus, LON bus, CAN bus, Ethernet, others on request. *Signal converter for external remote setpoint adjustment or control mode using 0/2 – 10 V signals. *Evaluation relay for PTC/PT100. *Buffered power supply unit *Measurement of electrical parameters, such as voltage, current, effective power, power factor, etc. *<I> on-site potential-free NC contact</I> ** <I>on-site potential-free NO contact</I> Order example: W-CTRL-CC-WP-2x20,0A-T4-DOL-BM-PKG Switchgear for 2 pumps with max. rated pump current of 20.0 A WP = version for borehole pump applications (well pump), contains the equipment described above T4 = mains connection 3~400 V DOL = activation type of the pump: direct BM = designed as switch cabinet floor model PKG = with packaging Scope of delivery *Switchgear *Installation and operating instructions *Circuit diagram
Wall-mounted installation
EV004216
EV002464
0
2540250
W-CTRL-CC-WP-1x44,0A-T4-DOL-WM-PKG
350
WILO SE
Comfort control system for all conventional pumps in glandless and glanded design with fixed speeds and three-phase motors.
Wilo-Comfort Controller for connecting pumps for water supply from bore holes and tanks. Fully electronic Comfort Controller (CC) in steel sheet housing as floor model or for wall fixation, RAL 7035 (structure), protection class IP54, completely wired. Switchgear suitable for connection to three-phase networks 3/PE 400 V/50 Hz in accordance with IEC 60038 (other voltages on request). Specially adjusted for borehole pumps from the Wilo catalogue. The Comfort Controller CC consists of: *Internal power supply *CPU (+ backup battery) *Analogue/digital modules *Power section with fuses, contactors and motor-protection equipment *Graphics-capable touch display with 3-colour backlight for indicating the operating status operation/fault/acknowledged fault, and supporting symbols and plain text for menu navigation in up to 27 languages, with European and Asiatic characters *3 user levels, display and selection of menu language, passwords, operating parameters, elapsed time indicator (individual and total operating hours), history memory for operating and error messages with time stamp via real time clock, pump status and control variable actual value display, diagram function *Main switch, internal Manual-0-Automatic service selector on each pump *Operating mode selection (Manual/Off/Automatic) for each pump via touch display *Potential-free contacts (changeover contact) for collective run and fault signals (SBM/SSM), individual operation and individual fault signals (EBM/ESM) and dry running signal for each pump *Evaluation relay (for each pump) for the connection of submersible electrodes for low-water cut-out switchgear (detachable for each pump with separated boreholes) *Digital inputs for switching external systems ON/OFF*, anti-frost protection alarm signal*, setpoint switchover** *Analogue input 0/4-20mA for external setpoint adjustment *Overload protection via thermal winding contact, motor protection via motor protection switch/in star-delta start-up, starting from 5.5 kW via thermal overload relay (optional: PTC/PT100 triggering available) *PID controller, automatic pump alteration and service life optimisation for multi-pump systems *Three setpoints are selectable by default *Automatic fault-actuated switchover to idle pump *Short test run of pump(s) during standstill, pilot pump function *Automatic, load-sensitive cut-in of peak-load pump depending on the programmable control variables Programmable control variables: *Pressure - constant, p-c *Differential pressure - constant, dp-c Option for live-zero evaluation for conductivity test (sensor/setpoint input), select from: *Signal and all drives full load *Signal and system deactivation *Signal and one pump at speed adjustable on frequency converter Additional charge for optional modules (installation in factory or later after technical clarification): *Temperature module *For connection to BMS systems in accordance with VDI 3814, via analogue/GSM modem, web server *For connection to bus systems: Modbus RTU, Profibus, LON bus, CAN bus, Ethernet, others on request. *Signal converter for external remote setpoint adjustment or control mode using 0/2 – 10 V signals. *Evaluation relay for PTC/PT100. *Buffered power supply unit *Measurement of electrical parameters, such as voltage, current, effective power, power factor, etc. *<I> on-site potential-free NC contact</I> ** <I>on-site potential-free NO contact</I> Order example: W-CTRL-CC-WP-2x20,0A-T4-DOL-BM-PKG Switchgear for 2 pumps with max. rated pump current of 20.0 A WP = version for borehole pump applications (well pump), contains the equipment described above T4 = mains connection 3~400 V DOL = activation type of the pump: direct BM = designed as switch cabinet floor model PKG = with packaging Scope of delivery *Switchgear *Installation and operating instructions *Circuit diagram
Wall-mounted installation
EV004216
EV002464
0
2540251
W-CTRL-CC-WP-2x44,0A-T4-DOL-WM-PKG
350
WILO SE
Comfort control system for all conventional pumps in glandless and glanded design with fixed speeds and three-phase motors.
Wilo-Comfort Controller for connecting pumps for water supply from bore holes and tanks. Fully electronic Comfort Controller (CC) in steel sheet housing as floor model or for wall fixation, RAL 7035 (structure), protection class IP54, completely wired. Switchgear suitable for connection to three-phase networks 3/PE 400 V/50 Hz in accordance with IEC 60038 (other voltages on request). Specially adjusted for borehole pumps from the Wilo catalogue. The Comfort Controller CC consists of: *Internal power supply *CPU (+ backup battery) *Analogue/digital modules *Power section with fuses, contactors and motor-protection equipment *Graphics-capable touch display with 3-colour backlight for indicating the operating status operation/fault/acknowledged fault, and supporting symbols and plain text for menu navigation in up to 27 languages, with European and Asiatic characters *3 user levels, display and selection of menu language, passwords, operating parameters, elapsed time indicator (individual and total operating hours), history memory for operating and error messages with time stamp via real time clock, pump status and control variable actual value display, diagram function *Main switch, internal Manual-0-Automatic service selector on each pump *Operating mode selection (Manual/Off/Automatic) for each pump via touch display *Potential-free contacts (changeover contact) for collective run and fault signals (SBM/SSM), individual operation and individual fault signals (EBM/ESM) and dry running signal for each pump *Evaluation relay (for each pump) for the connection of submersible electrodes for low-water cut-out switchgear (detachable for each pump with separated boreholes) *Digital inputs for switching external systems ON/OFF*, anti-frost protection alarm signal*, setpoint switchover** *Analogue input 0/4-20mA for external setpoint adjustment *Overload protection via thermal winding contact, motor protection via motor protection switch/in star-delta start-up, starting from 5.5 kW via thermal overload relay (optional: PTC/PT100 triggering available) *PID controller, automatic pump alteration and service life optimisation for multi-pump systems *Three setpoints are selectable by default *Automatic fault-actuated switchover to idle pump *Short test run of pump(s) during standstill, pilot pump function *Automatic, load-sensitive cut-in of peak-load pump depending on the programmable control variables Programmable control variables: *Pressure - constant, p-c *Differential pressure - constant, dp-c Option for live-zero evaluation for conductivity test (sensor/setpoint input), select from: *Signal and all drives full load *Signal and system deactivation *Signal and one pump at speed adjustable on frequency converter Additional charge for optional modules (installation in factory or later after technical clarification): *Temperature module *For connection to BMS systems in accordance with VDI 3814, via analogue/GSM modem, web server *For connection to bus systems: Modbus RTU, Profibus, LON bus, CAN bus, Ethernet, others on request. *Signal converter for external remote setpoint adjustment or control mode using 0/2 – 10 V signals. *Evaluation relay for PTC/PT100. *Buffered power supply unit *Measurement of electrical parameters, such as voltage, current, effective power, power factor, etc. *<I> on-site potential-free NC contact</I> ** <I>on-site potential-free NO contact</I> Order example: W-CTRL-CC-WP-2x20,0A-T4-DOL-BM-PKG Switchgear for 2 pumps with max. rated pump current of 20.0 A WP = version for borehole pump applications (well pump), contains the equipment described above T4 = mains connection 3~400 V DOL = activation type of the pump: direct BM = designed as switch cabinet floor model PKG = with packaging Scope of delivery *Switchgear *Installation and operating instructions *Circuit diagram
Wall-mounted installation
EV004216
EV002464
0
2540252
W-CTRL-CC-WP-1x61,0A-T4-DOL-WM-PKG
350
WILO SE
Comfort control system for all conventional pumps in glandless and glanded design with fixed speeds and three-phase motors.
Wilo-Comfort Controller for connecting pumps for water supply from bore holes and tanks. Fully electronic Comfort Controller (CC) in steel sheet housing as floor model or for wall fixation, RAL 7035 (structure), protection class IP54, completely wired. Switchgear suitable for connection to three-phase networks 3/PE 400 V/50 Hz in accordance with IEC 60038 (other voltages on request). Specially adjusted for borehole pumps from the Wilo catalogue. The Comfort Controller CC consists of: *Internal power supply *CPU (+ backup battery) *Analogue/digital modules *Power section with fuses, contactors and motor-protection equipment *Graphics-capable touch display with 3-colour backlight for indicating the operating status operation/fault/acknowledged fault, and supporting symbols and plain text for menu navigation in up to 27 languages, with European and Asiatic characters *3 user levels, display and selection of menu language, passwords, operating parameters, elapsed time indicator (individual and total operating hours), history memory for operating and error messages with time stamp via real time clock, pump status and control variable actual value display, diagram function *Main switch, internal Manual-0-Automatic service selector on each pump *Operating mode selection (Manual/Off/Automatic) for each pump via touch display *Potential-free contacts (changeover contact) for collective run and fault signals (SBM/SSM), individual operation and individual fault signals (EBM/ESM) and dry running signal for each pump *Evaluation relay (for each pump) for the connection of submersible electrodes for low-water cut-out switchgear (detachable for each pump with separated boreholes) *Digital inputs for switching external systems ON/OFF*, anti-frost protection alarm signal*, setpoint switchover** *Analogue input 0/4-20mA for external setpoint adjustment *Overload protection via thermal winding contact, motor protection via motor protection switch/in star-delta start-up, starting from 5.5 kW via thermal overload relay (optional: PTC/PT100 triggering available) *PID controller, automatic pump alteration and service life optimisation for multi-pump systems *Three setpoints are selectable by default *Automatic fault-actuated switchover to idle pump *Short test run of pump(s) during standstill, pilot pump function *Automatic, load-sensitive cut-in of peak-load pump depending on the programmable control variables Programmable control variables: *Pressure - constant, p-c *Differential pressure - constant, dp-c Option for live-zero evaluation for conductivity test (sensor/setpoint input), select from: *Signal and all drives full load *Signal and system deactivation *Signal and one pump at speed adjustable on frequency converter Additional charge for optional modules (installation in factory or later after technical clarification): *Temperature module *For connection to BMS systems in accordance with VDI 3814, via analogue/GSM modem, web server *For connection to bus systems: Modbus RTU, Profibus, LON bus, CAN bus, Ethernet, others on request. *Signal converter for external remote setpoint adjustment or control mode using 0/2 – 10 V signals. *Evaluation relay for PTC/PT100. *Buffered power supply unit *Measurement of electrical parameters, such as voltage, current, effective power, power factor, etc. *<I> on-site potential-free NC contact</I> ** <I>on-site potential-free NO contact</I> Order example: W-CTRL-CC-WP-2x20,0A-T4-DOL-BM-PKG Switchgear for 2 pumps with max. rated pump current of 20.0 A WP = version for borehole pump applications (well pump), contains the equipment described above T4 = mains connection 3~400 V DOL = activation type of the pump: direct BM = designed as switch cabinet floor model PKG = with packaging Scope of delivery *Switchgear *Installation and operating instructions *Circuit diagram
Wall-mounted installation
EV004216
EV002464
0
2540253
W-CTRL-CC-WP-2x61,0A-T4-DOL-WM-PKG
350
WILO SE
Comfort control system for all conventional pumps in glandless and glanded design with fixed speeds and three-phase motors.
Wilo-Comfort Controller for connecting pumps for water supply from bore holes and tanks. Fully electronic Comfort Controller (CC) in steel sheet housing as floor model or for wall fixation, RAL 7035 (structure), protection class IP54, completely wired. Switchgear suitable for connection to three-phase networks 3/PE 400 V/50 Hz in accordance with IEC 60038 (other voltages on request). Specially adjusted for borehole pumps from the Wilo catalogue. The Comfort Controller CC consists of: *Internal power supply *CPU (+ backup battery) *Analogue/digital modules *Power section with fuses, contactors and motor-protection equipment *Graphics-capable touch display with 3-colour backlight for indicating the operating status operation/fault/acknowledged fault, and supporting symbols and plain text for menu navigation in up to 27 languages, with European and Asiatic characters *3 user levels, display and selection of menu language, passwords, operating parameters, elapsed time indicator (individual and total operating hours), history memory for operating and error messages with time stamp via real time clock, pump status and control variable actual value display, diagram function *Main switch, internal Manual-0-Automatic service selector on each pump *Operating mode selection (Manual/Off/Automatic) for each pump via touch display *Potential-free contacts (changeover contact) for collective run and fault signals (SBM/SSM), individual operation and individual fault signals (EBM/ESM) and dry running signal for each pump *Evaluation relay (for each pump) for the connection of submersible electrodes for low-water cut-out switchgear (detachable for each pump with separated boreholes) *Digital inputs for switching external systems ON/OFF*, anti-frost protection alarm signal*, setpoint switchover** *Analogue input 0/4-20mA for external setpoint adjustment *Overload protection via thermal winding contact, motor protection via motor protection switch/in star-delta start-up, starting from 5.5 kW via thermal overload relay (optional: PTC/PT100 triggering available) *PID controller, automatic pump alteration and service life optimisation for multi-pump systems *Three setpoints are selectable by default *Automatic fault-actuated switchover to idle pump *Short test run of pump(s) during standstill, pilot pump function *Automatic, load-sensitive cut-in of peak-load pump depending on the programmable control variables Programmable control variables: *Pressure - constant, p-c *Differential pressure - constant, dp-c Option for live-zero evaluation for conductivity test (sensor/setpoint input), select from: *Signal and all drives full load *Signal and system deactivation *Signal and one pump at speed adjustable on frequency converter Additional charge for optional modules (installation in factory or later after technical clarification): *Temperature module *For connection to BMS systems in accordance with VDI 3814, via analogue/GSM modem, web server *For connection to bus systems: Modbus RTU, Profibus, LON bus, CAN bus, Ethernet, others on request. *Signal converter for external remote setpoint adjustment or control mode using 0/2 – 10 V signals. *Evaluation relay for PTC/PT100. *Buffered power supply unit *Measurement of electrical parameters, such as voltage, current, effective power, power factor, etc. *<I> on-site potential-free NC contact</I> ** <I>on-site potential-free NO contact</I> Order example: W-CTRL-CC-WP-2x20,0A-T4-DOL-BM-PKG Switchgear for 2 pumps with max. rated pump current of 20.0 A WP = version for borehole pump applications (well pump), contains the equipment described above T4 = mains connection 3~400 V DOL = activation type of the pump: direct BM = designed as switch cabinet floor model PKG = with packaging Scope of delivery *Switchgear *Installation and operating instructions *Circuit diagram
Wall-mounted installation
EV004216
EV002464
0
2540278
W-CTRL-CC-WP-1x13,0A-T4-SD-WM-PKG
350
WILO SE
Comfort control system for all conventional pumps in glandless and glanded design with fixed speeds and three-phase motors.
Wilo-Comfort Controller for connecting pumps for water supply from bore holes and tanks. Fully electronic Comfort Controller (CC) in steel sheet housing as floor model or for wall fixation, RAL 7035 (structure), protection class IP54, completely wired. Switchgear suitable for connection to three-phase networks 3/PE 400 V/50 Hz in accordance with IEC 60038 (other voltages on request). Specially adjusted for borehole pumps from the Wilo catalogue. The Comfort Controller CC consists of: *Internal power supply *CPU (+ backup battery) *Analogue/digital modules *Power section with fuses, contactors and motor-protection equipment *Graphics-capable touch display with 3-colour backlight for indicating the operating status operation/fault/acknowledged fault, and supporting symbols and plain text for menu navigation in up to 27 languages, with European and Asiatic characters *3 user levels, display and selection of menu language, passwords, operating parameters, elapsed time indicator (individual and total operating hours), history memory for operating and error messages with time stamp via real time clock, pump status and control variable actual value display, diagram function *Main switch, internal Manual-0-Automatic service selector on each pump *Operating mode selection (Manual/Off/Automatic) for each pump via touch display *Potential-free contacts (changeover contact) for collective run and fault signals (SBM/SSM), individual operation and individual fault signals (EBM/ESM) and dry running signal for each pump *Evaluation relay (for each pump) for the connection of submersible electrodes for low-water cut-out switchgear (detachable for each pump with separated boreholes) *Digital inputs for switching external systems ON/OFF*, anti-frost protection alarm signal*, setpoint switchover** *Analogue input 0/4-20mA for external setpoint adjustment *Overload protection via thermal winding contact, motor protection via motor protection switch/in star-delta start-up, starting from 5.5 kW via thermal overload relay (optional: PTC/PT100 triggering available) *PID controller, automatic pump alteration and service life optimisation for multi-pump systems *Three setpoints are selectable by default *Automatic fault-actuated switchover to idle pump *Short test run of pump(s) during standstill, pilot pump function *Automatic, load-sensitive cut-in of peak-load pump depending on the programmable control variables Programmable control variables: *Pressure - constant, p-c *Differential pressure - constant, dp-c Option for live-zero evaluation for conductivity test (sensor/setpoint input), select from: *Signal and all drives full load *Signal and system deactivation *Signal and one pump at speed adjustable on frequency converter Additional charge for optional modules (installation in factory or later after technical clarification): *Temperature module *For connection to BMS systems in accordance with VDI 3814, via analogue/GSM modem, web server *For connection to bus systems: Modbus RTU, Profibus, LON bus, CAN bus, Ethernet, others on request. *Signal converter for external remote setpoint adjustment or control mode using 0/2 – 10 V signals. *Evaluation relay for PTC/PT100. *Buffered power supply unit *Measurement of electrical parameters, such as voltage, current, effective power, power factor, etc. *<I> on-site potential-free NC contact</I> ** <I>on-site potential-free NO contact</I> Order example: W-CTRL-CC-WP-2x20,0A-T4-DOL-BM-PKG Switchgear for 2 pumps with max. rated pump current of 20.0 A WP = version for borehole pump applications (well pump), contains the equipment described above T4 = mains connection 3~400 V DOL = activation type of the pump: direct BM = designed as switch cabinet floor model PKG = with packaging Scope of delivery *Switchgear *Installation and operating instructions *Circuit diagram
Wall-mounted installation
EV004216
EV002464
0
2540279
W-CTRL-CC-WP-2x13,0A-T4-SD-WM-PKG
350
WILO SE
Comfort control system for all conventional pumps in glandless and glanded design with fixed speeds and three-phase motors.
Wilo-Comfort Controller for connecting pumps for water supply from bore holes and tanks. Fully electronic Comfort Controller (CC) in steel sheet housing as floor model or for wall fixation, RAL 7035 (structure), protection class IP54, completely wired. Switchgear suitable for connection to three-phase networks 3/PE 400 V/50 Hz in accordance with IEC 60038 (other voltages on request). Specially adjusted for borehole pumps from the Wilo catalogue. The Comfort Controller CC consists of: *Internal power supply *CPU (+ backup battery) *Analogue/digital modules *Power section with fuses, contactors and motor-protection equipment *Graphics-capable touch display with 3-colour backlight for indicating the operating status operation/fault/acknowledged fault, and supporting symbols and plain text for menu navigation in up to 27 languages, with European and Asiatic characters *3 user levels, display and selection of menu language, passwords, operating parameters, elapsed time indicator (individual and total operating hours), history memory for operating and error messages with time stamp via real time clock, pump status and control variable actual value display, diagram function *Main switch, internal Manual-0-Automatic service selector on each pump *Operating mode selection (Manual/Off/Automatic) for each pump via touch display *Potential-free contacts (changeover contact) for collective run and fault signals (SBM/SSM), individual operation and individual fault signals (EBM/ESM) and dry running signal for each pump *Evaluation relay (for each pump) for the connection of submersible electrodes for low-water cut-out switchgear (detachable for each pump with separated boreholes) *Digital inputs for switching external systems ON/OFF*, anti-frost protection alarm signal*, setpoint switchover** *Analogue input 0/4-20mA for external setpoint adjustment *Overload protection via thermal winding contact, motor protection via motor protection switch/in star-delta start-up, starting from 5.5 kW via thermal overload relay (optional: PTC/PT100 triggering available) *PID controller, automatic pump alteration and service life optimisation for multi-pump systems *Three setpoints are selectable by default *Automatic fault-actuated switchover to idle pump *Short test run of pump(s) during standstill, pilot pump function *Automatic, load-sensitive cut-in of peak-load pump depending on the programmable control variables Programmable control variables: *Pressure - constant, p-c *Differential pressure - constant, dp-c Option for live-zero evaluation for conductivity test (sensor/setpoint input), select from: *Signal and all drives full load *Signal and system deactivation *Signal and one pump at speed adjustable on frequency converter Additional charge for optional modules (installation in factory or later after technical clarification): *Temperature module *For connection to BMS systems in accordance with VDI 3814, via analogue/GSM modem, web server *For connection to bus systems: Modbus RTU, Profibus, LON bus, CAN bus, Ethernet, others on request. *Signal converter for external remote setpoint adjustment or control mode using 0/2 – 10 V signals. *Evaluation relay for PTC/PT100. *Buffered power supply unit *Measurement of electrical parameters, such as voltage, current, effective power, power factor, etc. *<I> on-site potential-free NC contact</I> ** <I>on-site potential-free NO contact</I> Order example: W-CTRL-CC-WP-2x20,0A-T4-DOL-BM-PKG Switchgear for 2 pumps with max. rated pump current of 20.0 A WP = version for borehole pump applications (well pump), contains the equipment described above T4 = mains connection 3~400 V DOL = activation type of the pump: direct BM = designed as switch cabinet floor model PKG = with packaging Scope of delivery *Switchgear *Installation and operating instructions *Circuit diagram
Wall-mounted installation
EV004216
EV002464
0
2540280
W-CTRL-CC-WP-1x19,0A-T4-SD-WM-PKG
350
WILO SE
Comfort control system for all conventional pumps in glandless and glanded design with fixed speeds and three-phase motors.
Wilo-Comfort Controller for connecting pumps for water supply from bore holes and tanks. Fully electronic Comfort Controller (CC) in steel sheet housing as floor model or for wall fixation, RAL 7035 (structure), protection class IP54, completely wired. Switchgear suitable for connection to three-phase networks 3/PE 400 V/50 Hz in accordance with IEC 60038 (other voltages on request). Specially adjusted for borehole pumps from the Wilo catalogue. The Comfort Controller CC consists of: *Internal power supply *CPU (+ backup battery) *Analogue/digital modules *Power section with fuses, contactors and motor-protection equipment *Graphics-capable touch display with 3-colour backlight for indicating the operating status operation/fault/acknowledged fault, and supporting symbols and plain text for menu navigation in up to 27 languages, with European and Asiatic characters *3 user levels, display and selection of menu language, passwords, operating parameters, elapsed time indicator (individual and total operating hours), history memory for operating and error messages with time stamp via real time clock, pump status and control variable actual value display, diagram function *Main switch, internal Manual-0-Automatic service selector on each pump *Operating mode selection (Manual/Off/Automatic) for each pump via touch display *Potential-free contacts (changeover contact) for collective run and fault signals (SBM/SSM), individual operation and individual fault signals (EBM/ESM) and dry running signal for each pump *Evaluation relay (for each pump) for the connection of submersible electrodes for low-water cut-out switchgear (detachable for each pump with separated boreholes) *Digital inputs for switching external systems ON/OFF*, anti-frost protection alarm signal*, setpoint switchover** *Analogue input 0/4-20mA for external setpoint adjustment *Overload protection via thermal winding contact, motor protection via motor protection switch/in star-delta start-up, starting from 5.5 kW via thermal overload relay (optional: PTC/PT100 triggering available) *PID controller, automatic pump alteration and service life optimisation for multi-pump systems *Three setpoints are selectable by default *Automatic fault-actuated switchover to idle pump *Short test run of pump(s) during standstill, pilot pump function *Automatic, load-sensitive cut-in of peak-load pump depending on the programmable control variables Programmable control variables: *Pressure - constant, p-c *Differential pressure - constant, dp-c Option for live-zero evaluation for conductivity test (sensor/setpoint input), select from: *Signal and all drives full load *Signal and system deactivation *Signal and one pump at speed adjustable on frequency converter Additional charge for optional modules (installation in factory or later after technical clarification): *Temperature module *For connection to BMS systems in accordance with VDI 3814, via analogue/GSM modem, web server *For connection to bus systems: Modbus RTU, Profibus, LON bus, CAN bus, Ethernet, others on request. *Signal converter for external remote setpoint adjustment or control mode using 0/2 – 10 V signals. *Evaluation relay for PTC/PT100. *Buffered power supply unit *Measurement of electrical parameters, such as voltage, current, effective power, power factor, etc. *<I> on-site potential-free NC contact</I> ** <I>on-site potential-free NO contact</I> Order example: W-CTRL-CC-WP-2x20,0A-T4-DOL-BM-PKG Switchgear for 2 pumps with max. rated pump current of 20.0 A WP = version for borehole pump applications (well pump), contains the equipment described above T4 = mains connection 3~400 V DOL = activation type of the pump: direct BM = designed as switch cabinet floor model PKG = with packaging Scope of delivery *Switchgear *Installation and operating instructions *Circuit diagram
Wall-mounted installation
EV004216
EV002464
0
2540281
W-CTRL-CC-WP-2x19,0A-T4-SD-WM-PKG
350
WILO SE
Comfort control system for all conventional pumps in glandless and glanded design with fixed speeds and three-phase motors.
Wilo-Comfort Controller for connecting pumps for water supply from bore holes and tanks. Fully electronic Comfort Controller (CC) in steel sheet housing as floor model or for wall fixation, RAL 7035 (structure), protection class IP54, completely wired. Switchgear suitable for connection to three-phase networks 3/PE 400 V/50 Hz in accordance with IEC 60038 (other voltages on request). Specially adjusted for borehole pumps from the Wilo catalogue. The Comfort Controller CC consists of: *Internal power supply *CPU (+ backup battery) *Analogue/digital modules *Power section with fuses, contactors and motor-protection equipment *Graphics-capable touch display with 3-colour backlight for indicating the operating status operation/fault/acknowledged fault, and supporting symbols and plain text for menu navigation in up to 27 languages, with European and Asiatic characters *3 user levels, display and selection of menu language, passwords, operating parameters, elapsed time indicator (individual and total operating hours), history memory for operating and error messages with time stamp via real time clock, pump status and control variable actual value display, diagram function *Main switch, internal Manual-0-Automatic service selector on each pump *Operating mode selection (Manual/Off/Automatic) for each pump via touch display *Potential-free contacts (changeover contact) for collective run and fault signals (SBM/SSM), individual operation and individual fault signals (EBM/ESM) and dry running signal for each pump *Evaluation relay (for each pump) for the connection of submersible electrodes for low-water cut-out switchgear (detachable for each pump with separated boreholes) *Digital inputs for switching external systems ON/OFF*, anti-frost protection alarm signal*, setpoint switchover** *Analogue input 0/4-20mA for external setpoint adjustment *Overload protection via thermal winding contact, motor protection via motor protection switch/in star-delta start-up, starting from 5.5 kW via thermal overload relay (optional: PTC/PT100 triggering available) *PID controller, automatic pump alteration and service life optimisation for multi-pump systems *Three setpoints are selectable by default *Automatic fault-actuated switchover to idle pump *Short test run of pump(s) during standstill, pilot pump function *Automatic, load-sensitive cut-in of peak-load pump depending on the programmable control variables Programmable control variables: *Pressure - constant, p-c *Differential pressure - constant, dp-c Option for live-zero evaluation for conductivity test (sensor/setpoint input), select from: *Signal and all drives full load *Signal and system deactivation *Signal and one pump at speed adjustable on frequency converter Additional charge for optional modules (installation in factory or later after technical clarification): *Temperature module *For connection to BMS systems in accordance with VDI 3814, via analogue/GSM modem, web server *For connection to bus systems: Modbus RTU, Profibus, LON bus, CAN bus, Ethernet, others on request. *Signal converter for external remote setpoint adjustment or control mode using 0/2 – 10 V signals. *Evaluation relay for PTC/PT100. *Buffered power supply unit *Measurement of electrical parameters, such as voltage, current, effective power, power factor, etc. *<I> on-site potential-free NC contact</I> ** <I>on-site potential-free NO contact</I> Order example: W-CTRL-CC-WP-2x20,0A-T4-DOL-BM-PKG Switchgear for 2 pumps with max. rated pump current of 20.0 A WP = version for borehole pump applications (well pump), contains the equipment described above T4 = mains connection 3~400 V DOL = activation type of the pump: direct BM = designed as switch cabinet floor model PKG = with packaging Scope of delivery *Switchgear *Installation and operating instructions *Circuit diagram
Wall-mounted installation
EV004216
EV002464
0
2540282
W-CTRL-CC-WP-1x24,0A-T4-SD-WM-PKG
350
WILO SE
Comfort control system for all conventional pumps in glandless and glanded design with fixed speeds and three-phase motors.
Wilo-Comfort Controller for connecting pumps for water supply from bore holes and tanks. Fully electronic Comfort Controller (CC) in steel sheet housing as floor model or for wall fixation, RAL 7035 (structure), protection class IP54, completely wired. Switchgear suitable for connection to three-phase networks 3/PE 400 V/50 Hz in accordance with IEC 60038 (other voltages on request). Specially adjusted for borehole pumps from the Wilo catalogue. The Comfort Controller CC consists of: *Internal power supply *CPU (+ backup battery) *Analogue/digital modules *Power section with fuses, contactors and motor-protection equipment *Graphics-capable touch display with 3-colour backlight for indicating the operating status operation/fault/acknowledged fault, and supporting symbols and plain text for menu navigation in up to 27 languages, with European and Asiatic characters *3 user levels, display and selection of menu language, passwords, operating parameters, elapsed time indicator (individual and total operating hours), history memory for operating and error messages with time stamp via real time clock, pump status and control variable actual value display, diagram function *Main switch, internal Manual-0-Automatic service selector on each pump *Operating mode selection (Manual/Off/Automatic) for each pump via touch display *Potential-free contacts (changeover contact) for collective run and fault signals (SBM/SSM), individual operation and individual fault signals (EBM/ESM) and dry running signal for each pump *Evaluation relay (for each pump) for the connection of submersible electrodes for low-water cut-out switchgear (detachable for each pump with separated boreholes) *Digital inputs for switching external systems ON/OFF*, anti-frost protection alarm signal*, setpoint switchover** *Analogue input 0/4-20mA for external setpoint adjustment *Overload protection via thermal winding contact, motor protection via motor protection switch/in star-delta start-up, starting from 5.5 kW via thermal overload relay (optional: PTC/PT100 triggering available) *PID controller, automatic pump alteration and service life optimisation for multi-pump systems *Three setpoints are selectable by default *Automatic fault-actuated switchover to idle pump *Short test run of pump(s) during standstill, pilot pump function *Automatic, load-sensitive cut-in of peak-load pump depending on the programmable control variables Programmable control variables: *Pressure - constant, p-c *Differential pressure - constant, dp-c Option for live-zero evaluation for conductivity test (sensor/setpoint input), select from: *Signal and all drives full load *Signal and system deactivation *Signal and one pump at speed adjustable on frequency converter Additional charge for optional modules (installation in factory or later after technical clarification): *Temperature module *For connection to BMS systems in accordance with VDI 3814, via analogue/GSM modem, web server *For connection to bus systems: Modbus RTU, Profibus, LON bus, CAN bus, Ethernet, others on request. *Signal converter for external remote setpoint adjustment or control mode using 0/2 – 10 V signals. *Evaluation relay for PTC/PT100. *Buffered power supply unit *Measurement of electrical parameters, such as voltage, current, effective power, power factor, etc. *<I> on-site potential-free NC contact</I> ** <I>on-site potential-free NO contact</I> Order example: W-CTRL-CC-WP-2x20,0A-T4-DOL-BM-PKG Switchgear for 2 pumps with max. rated pump current of 20.0 A WP = version for borehole pump applications (well pump), contains the equipment described above T4 = mains connection 3~400 V DOL = activation type of the pump: direct BM = designed as switch cabinet floor model PKG = with packaging Scope of delivery *Switchgear *Installation and operating instructions *Circuit diagram
Wall-mounted installation
EV004216
EV002464
0
2540283
W-CTRL-CC-WP-2x24,0A-T4-SD-WM-PKG
350
WILO SE
Comfort control system for all conventional pumps in glandless and glanded design with fixed speeds and three-phase motors.
Wilo-Comfort Controller for connecting pumps for water supply from bore holes and tanks. Fully electronic Comfort Controller (CC) in steel sheet housing as floor model or for wall fixation, RAL 7035 (structure), protection class IP54, completely wired. Switchgear suitable for connection to three-phase networks 3/PE 400 V/50 Hz in accordance with IEC 60038 (other voltages on request). Specially adjusted for borehole pumps from the Wilo catalogue. The Comfort Controller CC consists of: *Internal power supply *CPU (+ backup battery) *Analogue/digital modules *Power section with fuses, contactors and motor-protection equipment *Graphics-capable touch display with 3-colour backlight for indicating the operating status operation/fault/acknowledged fault, and supporting symbols and plain text for menu navigation in up to 27 languages, with European and Asiatic characters *3 user levels, display and selection of menu language, passwords, operating parameters, elapsed time indicator (individual and total operating hours), history memory for operating and error messages with time stamp via real time clock, pump status and control variable actual value display, diagram function *Main switch, internal Manual-0-Automatic service selector on each pump *Operating mode selection (Manual/Off/Automatic) for each pump via touch display *Potential-free contacts (changeover contact) for collective run and fault signals (SBM/SSM), individual operation and individual fault signals (EBM/ESM) and dry running signal for each pump *Evaluation relay (for each pump) for the connection of submersible electrodes for low-water cut-out switchgear (detachable for each pump with separated boreholes) *Digital inputs for switching external systems ON/OFF*, anti-frost protection alarm signal*, setpoint switchover** *Analogue input 0/4-20mA for external setpoint adjustment *Overload protection via thermal winding contact, motor protection via motor protection switch/in star-delta start-up, starting from 5.5 kW via thermal overload relay (optional: PTC/PT100 triggering available) *PID controller, automatic pump alteration and service life optimisation for multi-pump systems *Three setpoints are selectable by default *Automatic fault-actuated switchover to idle pump *Short test run of pump(s) during standstill, pilot pump function *Automatic, load-sensitive cut-in of peak-load pump depending on the programmable control variables Programmable control variables: *Pressure - constant, p-c *Differential pressure - constant, dp-c Option for live-zero evaluation for conductivity test (sensor/setpoint input), select from: *Signal and all drives full load *Signal and system deactivation *Signal and one pump at speed adjustable on frequency converter Additional charge for optional modules (installation in factory or later after technical clarification): *Temperature module *For connection to BMS systems in accordance with VDI 3814, via analogue/GSM modem, web server *For connection to bus systems: Modbus RTU, Profibus, LON bus, CAN bus, Ethernet, others on request. *Signal converter for external remote setpoint adjustment or control mode using 0/2 – 10 V signals. *Evaluation relay for PTC/PT100. *Buffered power supply unit *Measurement of electrical parameters, such as voltage, current, effective power, power factor, etc. *<I> on-site potential-free NC contact</I> ** <I>on-site potential-free NO contact</I> Order example: W-CTRL-CC-WP-2x20,0A-T4-DOL-BM-PKG Switchgear for 2 pumps with max. rated pump current of 20.0 A WP = version for borehole pump applications (well pump), contains the equipment described above T4 = mains connection 3~400 V DOL = activation type of the pump: direct BM = designed as switch cabinet floor model PKG = with packaging Scope of delivery *Switchgear *Installation and operating instructions *Circuit diagram
Wall-mounted installation
EV004216
EV002464
0
2540284
W-CTRL-CC-WP-1x32,0A-T4-SD-WM-PKG
350
WILO SE
Comfort control system for all conventional pumps in glandless and glanded design with fixed speeds and three-phase motors.
Wilo-Comfort Controller for connecting pumps for water supply from bore holes and tanks. Fully electronic Comfort Controller (CC) in steel sheet housing as floor model or for wall fixation, RAL 7035 (structure), protection class IP54, completely wired. Switchgear suitable for connection to three-phase networks 3/PE 400 V/50 Hz in accordance with IEC 60038 (other voltages on request). Specially adjusted for borehole pumps from the Wilo catalogue. The Comfort Controller CC consists of: *Internal power supply *CPU (+ backup battery) *Analogue/digital modules *Power section with fuses, contactors and motor-protection equipment *Graphics-capable touch display with 3-colour backlight for indicating the operating status operation/fault/acknowledged fault, and supporting symbols and plain text for menu navigation in up to 27 languages, with European and Asiatic characters *3 user levels, display and selection of menu language, passwords, operating parameters, elapsed time indicator (individual and total operating hours), history memory for operating and error messages with time stamp via real time clock, pump status and control variable actual value display, diagram function *Main switch, internal Manual-0-Automatic service selector on each pump *Operating mode selection (Manual/Off/Automatic) for each pump via touch display *Potential-free contacts (changeover contact) for collective run and fault signals (SBM/SSM), individual operation and individual fault signals (EBM/ESM) and dry running signal for each pump *Evaluation relay (for each pump) for the connection of submersible electrodes for low-water cut-out switchgear (detachable for each pump with separated boreholes) *Digital inputs for switching external systems ON/OFF*, anti-frost protection alarm signal*, setpoint switchover** *Analogue input 0/4-20mA for external setpoint adjustment *Overload protection via thermal winding contact, motor protection via motor protection switch/in star-delta start-up, starting from 5.5 kW via thermal overload relay (optional: PTC/PT100 triggering available) *PID controller, automatic pump alteration and service life optimisation for multi-pump systems *Three setpoints are selectable by default *Automatic fault-actuated switchover to idle pump *Short test run of pump(s) during standstill, pilot pump function *Automatic, load-sensitive cut-in of peak-load pump depending on the programmable control variables Programmable control variables: *Pressure - constant, p-c *Differential pressure - constant, dp-c Option for live-zero evaluation for conductivity test (sensor/setpoint input), select from: *Signal and all drives full load *Signal and system deactivation *Signal and one pump at speed adjustable on frequency converter Additional charge for optional modules (installation in factory or later after technical clarification): *Temperature module *For connection to BMS systems in accordance with VDI 3814, via analogue/GSM modem, web server *For connection to bus systems: Modbus RTU, Profibus, LON bus, CAN bus, Ethernet, others on request. *Signal converter for external remote setpoint adjustment or control mode using 0/2 – 10 V signals. *Evaluation relay for PTC/PT100. *Buffered power supply unit *Measurement of electrical parameters, such as voltage, current, effective power, power factor, etc. *<I> on-site potential-free NC contact</I> ** <I>on-site potential-free NO contact</I> Order example: W-CTRL-CC-WP-2x20,0A-T4-DOL-BM-PKG Switchgear for 2 pumps with max. rated pump current of 20.0 A WP = version for borehole pump applications (well pump), contains the equipment described above T4 = mains connection 3~400 V DOL = activation type of the pump: direct BM = designed as switch cabinet floor model PKG = with packaging Scope of delivery *Switchgear *Installation and operating instructions *Circuit diagram
Wall-mounted installation
EV004216
EV002464
0
2540285
W-CTRL-CC-WP-2x32,0A-T4-SD-WM-PKG
350
WILO SE
Comfort control system for all conventional pumps in glandless and glanded design with fixed speeds and three-phase motors.
Wilo-Comfort Controller for connecting pumps for water supply from bore holes and tanks. Fully electronic Comfort Controller (CC) in steel sheet housing as floor model or for wall fixation, RAL 7035 (structure), protection class IP54, completely wired. Switchgear suitable for connection to three-phase networks 3/PE 400 V/50 Hz in accordance with IEC 60038 (other voltages on request). Specially adjusted for borehole pumps from the Wilo catalogue. The Comfort Controller CC consists of: *Internal power supply *CPU (+ backup battery) *Analogue/digital modules *Power section with fuses, contactors and motor-protection equipment *Graphics-capable touch display with 3-colour backlight for indicating the operating status operation/fault/acknowledged fault, and supporting symbols and plain text for menu navigation in up to 27 languages, with European and Asiatic characters *3 user levels, display and selection of menu language, passwords, operating parameters, elapsed time indicator (individual and total operating hours), history memory for operating and error messages with time stamp via real time clock, pump status and control variable actual value display, diagram function *Main switch, internal Manual-0-Automatic service selector on each pump *Operating mode selection (Manual/Off/Automatic) for each pump via touch display *Potential-free contacts (changeover contact) for collective run and fault signals (SBM/SSM), individual operation and individual fault signals (EBM/ESM) and dry running signal for each pump *Evaluation relay (for each pump) for the connection of submersible electrodes for low-water cut-out switchgear (detachable for each pump with separated boreholes) *Digital inputs for switching external systems ON/OFF*, anti-frost protection alarm signal*, setpoint switchover** *Analogue input 0/4-20mA for external setpoint adjustment *Overload protection via thermal winding contact, motor protection via motor protection switch/in star-delta start-up, starting from 5.5 kW via thermal overload relay (optional: PTC/PT100 triggering available) *PID controller, automatic pump alteration and service life optimisation for multi-pump systems *Three setpoints are selectable by default *Automatic fault-actuated switchover to idle pump *Short test run of pump(s) during standstill, pilot pump function *Automatic, load-sensitive cut-in of peak-load pump depending on the programmable control variables Programmable control variables: *Pressure - constant, p-c *Differential pressure - constant, dp-c Option for live-zero evaluation for conductivity test (sensor/setpoint input), select from: *Signal and all drives full load *Signal and system deactivation *Signal and one pump at speed adjustable on frequency converter Additional charge for optional modules (installation in factory or later after technical clarification): *Temperature module *For connection to BMS systems in accordance with VDI 3814, via analogue/GSM modem, web server *For connection to bus systems: Modbus RTU, Profibus, LON bus, CAN bus, Ethernet, others on request. *Signal converter for external remote setpoint adjustment or control mode using 0/2 – 10 V signals. *Evaluation relay for PTC/PT100. *Buffered power supply unit *Measurement of electrical parameters, such as voltage, current, effective power, power factor, etc. *<I> on-site potential-free NC contact</I> ** <I>on-site potential-free NO contact</I> Order example: W-CTRL-CC-WP-2x20,0A-T4-DOL-BM-PKG Switchgear for 2 pumps with max. rated pump current of 20.0 A WP = version for borehole pump applications (well pump), contains the equipment described above T4 = mains connection 3~400 V DOL = activation type of the pump: direct BM = designed as switch cabinet floor model PKG = with packaging Scope of delivery *Switchgear *Installation and operating instructions *Circuit diagram
Wall-mounted installation
EV004216
EV002464
0
显示压缩表示(368 konfigurierbares Produkt)
订购编码2540253_EV004216_EV002464_1000
上次修改16.06.2026 08:20:47
单位

分类

CNS

CNSERPBASE Object Properties
Order Number2540253_EV004216_EV002464_1000

Revit

RVT_METRICGENERICMODEL (Metric) Generic Model
比较多个部件
Min. 2 产品,含 添加