Doepke DHi 5 09917986

展开表
1/5
PREVIEW
Product number of the Manufacturer
MANUID
Manufacturer Type Description
MANUTYPEDESC
Level of Geometry
LOG
Short Description
DESCSHORT
Long Description
DESCLONG
International product number
INTNO
Manufacturer Name
MANUNAME
Delivery Time
DELTIME
Device fitting
EF007826
Function
EF000030
1
2
3
4
5
6
7
8
9
10
11
09200032
DRCBO 4 Hi 2
300
Auxiliary switch for RCBO 3+N, 230V, 6A, 1CO, operating lever blue
Auxiliary switches report the status of the main devices to which they are fitted. The DRCBO 4 Hi 2 auxiliary switches are suitable for RCBOs in the DRCBO 4 series with a blue knob. The operating state of the circuit-breaker can be displayed with the aid of signalling devices.The DRCBO 4 Hi 2 auxiliary switches are suitable for RCBOs in the DRCBO 4 series with a blue knob. The operating state of the circuit-breaker can be displayed using signalling devices.
4014712273740
Doepke Schaltgeräte GmbH
35
Earth leakage circuit breaker
Auxiliary switch/fault-signal switch
09200040
DHi 11/DFS2/4
300
Auxiliary/error signal switch for DFS, 230V AC/DC, max. 6A, 1NC/1CO
Auxiliary switches report the status of the main devices to which they are fitted. DHi 11 are optional auxiliary switches and error signal switches for Doepke residual current circuit-breakers in the DFS and DHS series. DHi 11 are suitable for switches with blue toggle. They signal the switch-on and switch-off of the RCCB in "auxiliary switch" operating mode; only tripping is signalled in "error signal switch" operating mode.
4014712198388
Doepke Schaltgeräte GmbH
20
Earth leakage switch
Auxiliary switch/fault-signal switch
09917984
DHi 3
300
Auxiliary switch for DLS 6, 230V AC, max. 10A, 1NO
Auxiliary switches report the status of the main devices to which they are fitted. Auxiliary switches DHi 3 to DHi 8 can be retro-fitted to miniature circuit-breakers from series DLS 6 h, hsl or i. The auxiliary switch activates in parallel to the DLS 6 miniature circuit-breaker when switched off by hand or because of overload or short-circuit. Other indicators (buzzers, indicator light, etc.) can be used to display the operating status of a miniature circuit-breaker.
4014712197275
Doepke Schaltgeräte GmbH
56
Miniature circuit breaker (MCB)
Auxiliary switch
09917985
DHi 4
300
Auxiliary switch for DLS 6, 230V AC, max. 10A, 1NC/1NO
Auxiliary switches report the status of the main devices to which they are fitted. Auxiliary switches DHi 3 to DHi 8 can be retro-fitted to miniature circuit-breakers from series DLS 6 h, hsl or i. The auxiliary switch activates in parallel to the DLS 6 miniature circuit-breaker when switched off by hand or because of overload or short-circuit. Other indicators (buzzers, indicator light, etc.) can be used to display the operating status of a miniature circuit-breaker.
4014712197282
Doepke Schaltgeräte GmbH
20
Miniature circuit breaker (MCB)
Auxiliary switch
09917986
DHi 5
300
Auxiliary switch for DLS 6, 230V AC, max. 10A, 2NC/1NO
Auxiliary switches report the status of the main devices to which they are fitted. Auxiliary switches DHi 3 to DHi 8 can be retro-fitted to miniature circuit-breakers from series DLS 6 h, hsl or i. The auxiliary switch activates in parallel to the DLS 6 miniature circuit-breaker when switched off by hand or because of overload or short-circuit. Other indicators (buzzers, indicator light, etc.) can be used to display the operating status of a miniature circuit-breaker.
4014712197299
Doepke Schaltgeräte GmbH
56
Miniature circuit breaker (MCB)
Auxiliary switch
09917987
DHi 6
300
Auxiliary switch for DLS 6, 230V AC, max. 10A, 1NC/2NO
Auxiliary switches report the status of the main devices to which they are fitted. Auxiliary switches DHi 3 to DHi 8 can be retro-fitted to miniature circuit-breakers from series DLS 6 h, hsl or i. The auxiliary switch activates in parallel to the DLS 6 miniature circuit-breaker when switched off by hand or because of overload or short-circuit. Other indicators (buzzers, indicator light, etc.) can be used to display the operating status of a miniature circuit-breaker.
4014712197305
Doepke Schaltgeräte GmbH
56
Miniature circuit breaker (MCB)
Auxiliary switch
09917988
DHi 7
300
Auxiliary switch for DLS 6, 230V AC, max. 4.8A, 1CO
Auxiliary switches report the status of the main devices to which they are fitted. Auxiliary switches DHi 3 to DHi 8 can be retro-fitted to miniature circuit-breakers from series DLS 6 h, hsl or i. The auxiliary switch activates in parallel to the DLS 6 miniature circuit-breaker when switched off by hand or because of overload or short-circuit. Other indicators (buzzers, indicator light, etc.) can be used to display the operating status of a miniature circuit-breaker.
4014712197312
Doepke Schaltgeräte GmbH
56
Miniature circuit breaker (MCB)
Auxiliary switch
09917989
DHi 8
300
Auxiliary switch for DLS 6, 230V AC, max. 4.8A, 2CO, Mounting side right
Auxiliary switches report the status of the main devices to which they are fitted. Auxiliary switches DHi 3 to DHi 8 can be retro-fitted to miniature circuit-breakers from series DLS 6 h, hsl or i. The auxiliary switch activates in parallel to the DLS 6 miniature circuit-breaker when switched off by hand or because of overload or short-circuit. Other indicators (buzzers, indicator light, etc.) can be used to display the operating status of a miniature circuit-breaker.
4014712197329
Doepke Schaltgeräte GmbH
56
Miniature circuit breaker (MCB)
Auxiliary switch
09917990
DHi-S10
300
Auxiliary/error signal switch for DLS 6, 230V AC, max. 4.8A, 1CO
Auxiliary switches report the status of the main devices to which they are fitted. Fault signal auxiliary switches DHi-S can be retro-fitted to miniature circuit-breakers from series DLS 6 (h, hsl or i). The fault signal switch only activates when the miniature circuit-breaker has switched off due to overload or short-circuit. Other signal devices (buzzers, indicator light, etc.) can then be used to indicate the operating status of the fault signal switch or for other control processes.
4014712197336
Doepke Schaltgeräte GmbH
56
Miniature circuit breaker (MCB)
Auxiliary switch/fault-signal switch
09917991
DHi-S11
300
Auxiliary/error signal switch for DLS 6, 230V AC, max. 4.8A, 2CO
Auxiliary switches report the status of the main devices to which they are fitted. Fault signal auxiliary switches DHi-S can be retro-fitted to miniature circuit-breakers from series DLS 6 (h, hsl or i). The fault signal switch only activates when the miniature circuit-breaker has switched off due to overload or short-circuit. Other signal devices (buzzers, indicator light, etc.) can then be used to indicate the operating status of the fault signal switch or for other control processes.
4014712197343
Doepke Schaltgeräte GmbH
56
Miniature circuit breaker (MCB)
Auxiliary switch/fault-signal switch
09200030
DRCBO 4 Hi 1
300
Auxiliary switch for RCBO 3+N, 230V, 6A, 1CO, operating lever black
Auxiliary switches report the status of the main devices to which they are fitted. The DRCBO 4 Hi 1 auxiliary switches are suitable for RCCB/MCB combinations of the FIB and FIC series in the design type A 3+N as well as type B. This makes it possible to display the operating status of the circuit breaker using signalling devices.
4014712221437
Doepke Schaltgeräte GmbH
28
Earth leakage circuit breaker
Auxiliary switch/fault-signal switch
显示压缩表示(11 konfigurierbares Produkt)
订购编码09917986
简短文本Auxiliary switch for DLS 6, 230V AC, max. 10A, 2NC/1NO
长���Auxiliary switches report the status of the main devices to which they are fitted. Auxiliary switches DHi 3 to DHi 8 can be retro-fitted to miniature circuit-breakers from series DLS 6 h, hsl or i. The auxiliary switch activates in parallel to the DLS 6 miniature circuit-breaker when switched off by hand or because of overload or short-circuit. Other indicators (buzzers, indicator light, etc.) can be used to display the operating status of a miniature circuit-breaker.
上次修改16.10.2026 10:22:34
单位

分类

CNS

CNSERPBASE Object Properties
REACH认证false
RoHS认证true
Customs Tariff Number85362010
Description longAuxiliary switches report the status of the main devices to which they are fitted. Auxiliary switches DHi 3 to DHi 8 can be retro-fitted to miniature circuit-breakers from series DLS 6 h, hsl or i. The auxiliary switch activates in parallel to the DLS 6 miniature circuit-breaker when switched off by hand or because of overload or short-circuit. Other indicators (buzzers, indicator light, etc.) can be used to display the operating status of a miniature circuit-breaker.
Description shortAuxiliary switch for DLS 6, 230V AC, max. 10A, 2NC/1NO
GTIN-Code4014712197299
Order Number09917986
Product websitehttps://www.doepke.de/en/products/09917986
Quantity Minimum1
Type CodeDHi 5
CNSPHYPROP Physical Properties

ECLASS 14.0

27-37-13-02 辅助开关装置
净重0.055 kg
额定电流10 A
厂商产品编号09917986
制造商名称Doepke
附加链接地址https://www.doepke.de/en/products/switching-devices/rcbo/type-b/tripping-characteristic-b/09917986/
极数1
制造商产品说明Auxiliary switch for DLS 6, 230 V AC, ... max. 10 A, 2 NC/1 NO
高度87 mm
损耗功率0 W
深度68.3 mm
宽度8.8 mm
额定电压230 V
27-14-35-02 抑制触点/信号接点

ECLASS 13.0

27-14-35-02 抑制触点/信号接点
操纵方法AC
额定电压230 V
Width in units of measurement0.5
rated switch current10.0 A
number of fault-signal switches0
device fittingMiniature circuit breaker (MCB)
断开触点数量2
闭合触点数量1
转换器数量0
auto test for earth leakage function presentfalse
suitable for max. number of poles of main contact unit4
suitable for max. current main contact unit125 A

ETIM 10.0

EC001286 Auxiliary device for distribution board devices
FunctionAuxiliary switch
Voltage typeAC
Rated voltage230 V
Width in number of modular spacings0.5
Rated switch current10.0 A
Number of fault-signal switches0
Device fittingMiniature circuit breaker (MCB)
Number of contacts as normally closed contact2
Number of contacts as normally open contact1
Number of contacts as change-over contact0
With auto test for earth leakage functionfalse
Suitable for max. number of poles main contact unit (total)4
Suitable for max. current main contact unit125 A

ETIM 9.0

EC001286 Auxiliary device for distribution board devices
FunctionAuxiliary switch
Voltage typeAC
Rated voltage230 V
Width in number of modular spacings0.5
Rated switch current10.0 A
Number of fault-signal switches0
Device fittingMiniature circuit breaker (MCB)
Number of contacts as normally closed contact2
Number of contacts as normally open contact1
Number of contacts as change-over contact0
With auto test for earth leakage functionfalse
Suitable for max. number of poles main contact unit (total)4
Suitable for max. current main contact unit125 A