二维搜索
Sketch the part you are looking for or have a photo described in text form
Create image description with AI
Create image description with AI
Drop file here
支持的文件格式: .PNG, .JPG, .JPEG, .WEBP
1/5
1
1
2|0
3
4
4
0
0
0
0
0
0
0
0
0
0

ABB - 1SAT112000R1011 + HF0.6-DOL-24VDC

Expand Table
1/5
Product Id
PN
Extended Product Type
EXTTYPE
Type
TYPE
Description
DES
Long Description
DESCLONG
International product number
INTNO
Product number of the Manufacturer
MANUID
Type of motor starter
EF009598
With short-circuit release
EF006691
Rated control supply voltage Us at AC 50HZ
EF003978 [V]
1
2
3
1SAT112000R1011
HF0.6-DOL-24VDC
HFx-DOL
Electronic Compact Starter, direct-on-line starter with overload protection
The HF-DOL-range is used for the direct-on-line start of motors and the switching of non-resistive loads. With contactor and overload relay functionalities integrated into one device, the results are faster wiring times and fewer faults. The range covers 0.6 A, 2.4 A and up to 9 A - for motors up to 3 kW – 500 V AC. The integrated electronic overload protection has a wide setting range that enables just three models to cover all requirements. Setting range of HF0.6-DOL-24VDC is 0.075 A to 0.6 A. The control supply voltage is 24 V DC. For the control and main connection points ABB offers screw connections. ABB also offers a HF-DOLE safety range with emergency stop function. This offers Safety Integrity Level 3 in accordance with functional safety standard IEC 61508-1 and Performance Level 'e' in accordance with ISO 13849-1. The safety range is ATEX-certified.
4013614515576
1SAT112000R1011
Direct online starter (DOL)
false
0 - 0
1SAT122000R1011
HF2.4-DOL-24VDC
HFx-DOL
Electronic Compact Starter, direct-on-line starter with overload protection
The HF-DOL-range is used for the direct-on-line start of motors and the switching of non-resistive loads. With contactor and overload relay functionalities integrated into one device, the results are faster wiring times and fewer faults. The range covers 0.6 A, 2.4 A and up to 9 A - for motors up to 3 kW – 500 V AC. The integrated electronic overload protection has a wide setting range that enables just three models to cover all requirements. Setting range of HF2.4-DOL-24VDC is 0.18 A to 2.4 A. The control supply voltage is 24 V DC. For the control and main connection points ABB offers screw connections. ABB also offers a HF-DOLE safety range with emergency stop function. This offers Safety Integrity Level 3 in accordance with functional safety standard IEC 61508-1 and Performance Level 'e' in accordance with ISO 13849-1. The safety range is ATEX-certified.
4013614515583
1SAT122000R1011
Direct online starter (DOL)
false
0 - 0
1SAT142000R1011
HF9-DOL-24VDC
HFx-DOL
Electronic Compact Starter, direct-on-line starter with overload protection
The HF-DOL-range is used for the direct-on-line start of motors and the switching of non-resistive loads. With contactor and overload relay functionalities integrated into one device, the results are faster wiring times and fewer faults. The range covers 0.6 A, 2.4 A and up to 9 A - for motors up to 3 kW – 500 V AC. The integrated electronic overload protection has a wide setting range that enables just three models to cover all requirements. Setting range of HF9-DOL-24VDC is 1.5 A to 9 A. The control supply voltage is 24 V DC. For the control and main connection points ABB offers screw connections. ABB also offers a HF-DOLE safety range with emergency stop function. This offers Safety Integrity Level 3 in accordance with functional safety standard IEC 61508-1 and Performance Level 'e' in accordance with ISO 13849-1. The safety range is ATEX-certified.
4013614515590
1SAT142000R1011
Direct online starter (DOL)
false
0 - 0
显示压缩表示形式 (3 Produkt)
订购编码1SAT112000R1011
ShorttextHF0.6-DOL-24VDC Electronic Compact Starter
LongtextThe HF-DOL-range is used for the direct-on-line start of motors and the switching of non-resistive loads. With contactor and overload relay functionalities integrated into one device, the results are faster wiring times and fewer faults. The range covers 0.6 A, 2.4 A and up to 9 A - for motors up to 3 kW – 500 V AC. The integrated electronic overload protection has a wide setting range that enables just three models to cover all requirements. Setting range of HF0.6-DOL-24VDC is 0.075 A to 0.6 A. The control supply voltage is 24 V DC. For the control and main connection points ABB offers screw connections. ABB also offers a HF-DOLE safety range with emergency stop function. This offers Safety Integrity Level 3 in accordance with functional safety standard IEC 61508-1 and Performance Level 'e' in accordance with ISO 13849-1. The safety range is ATEX-certified.
上次修改25.07.2024 13:26:09
单位

分类

CNS

CNSERPBASE Object Properties
Customs Tariff Number85371098
Description longThe HF-DOL-range is used for the direct-on-line start of motors and the switching of non-resistive loads. With contactor and overload relay functionalities integrated into one device, the results are faster wiring times and fewer faults. The range covers 0.6 A, 2.4 A and up to 9 A - for motors up to 3 kW – 500 V AC. The integrated electronic overload protection has a wide setting range that enables just three models to cover all requirements. Setting range of HF0.6-DOL-24VDC is 0.075 A to 0.6 A. The control supply voltage is 24 V DC. For the control and main connection points ABB offers screw connections. ABB also offers a HF-DOLE safety range with emergency stop function. This offers Safety Integrity Level 3 in accordance with functional safety standard IEC 61508-1 and Performance Level 'e' in accordance with ISO 13849-1. The safety range is ATEX-certified.
Description shortHF0.6-DOL-24VDC Electronic Compact Starter
GTIN-Code4013614515576
Order Number1SAT112000R1011
Product websitehttps://new.abb.com/products/ABB1SAT112000R1011

ECLASS 14.0

27-37-09-05 电动机联合启动器
27-02-40-02 发动机起动机

ECLASS 12.0

27-37-09-05 电动机联合启动器

ETIM 10.0

EC001037 Motor starter/motor starter combination

ETIM 8.0

EC001037 Motor starter/Motor starter combination
With transformerfalse
Rated operation power at AC-3, 400 V0.18
Number of command positions16
Suitable for emergency stopfalse
Rated operation current Ie0.6
Number of indicator lights4
Overload release current setting0.075 - 0.600
Supporting protocol for LONfalse
Supporting protocol for TCP/IPfalse
Supporting protocol for ASIfalse
Supporting protocol for PROFIBUSfalse
Supporting protocol for CANfalse
Supporting protocol for INTERBUSfalse
Supporting protocol for Modbusfalse
Supporting protocol for Data-Highwayfalse
Supporting protocol for DeviceNetfalse
Supporting protocol for SUCONETfalse
Supporting protocol for other bus systemsfalse
External reset possibletrue
Rail mounting possibletrue
Rated control supply voltage Us at AC 50HZ0 - 0
Rated control supply voltage Us at AC 60HZ0 - 0
Rated control supply voltage Us at DC24 - 24
Supporting protocol for SERCOSfalse
Supporting protocol for INTERBUS-Safetyfalse
With short-circuit releasefalse
With fusefalse
Supporting protocol for AS-Interface Safety at Workfalse
Supporting protocol for DeviceNet Safetyfalse
Supporting protocol for EtherNet/IPfalse
Supporting protocol for Foundation Fieldbusfalse
Supporting protocol for PROFINET CBAfalse
Supporting protocol for PROFINET IOfalse
Supporting protocol for PROFIsafefalse
Supporting protocol for SafetyBUS pfalse
Type of motor starterDirect online starter (DOL)
Rated operation power at AC-3, 230 V, 3-phase0.09
Rated operation current at AC-3, 400 V0.6
Ambient temperature, upper operating limit80
Temperature compensated overload protectiontrue