DP3T9840Z11A

Expand Table
EN
1/5
Part Number
CODE
Casing Material
MATCASING
Width
WIDTH [mm]
Electrical connections
INLETS
IP protection rating
IP
Actuating Head
ACT
Head Material
MATHEAD
Microswitch
CONTACTS
Approvals
APP
Reference Directives
DIR
Reference standards
STDR
Operating Temperatures
TEMP [°C]
Stock temperature
TEMPSTOCK [°C]
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
DP2T9840Z11A
Reinforced thermoplastic
50
Two PG11 threaded cable entries and a 1/2 "NPT cable gland adapter
IP65
Pull wire ring
Thermoplastic head
Snap action contacts (1NO + 1NC)
IMQ - cULus - CCC - CSA - EAC
LVD - 2014/35/EU
IEC 60947-5-1 / EN 60947-5-1
-40°C … +70°C
-40°C … +80°C
DP2T98W02A
Reinforced thermoplastic
50
Two PG11 threaded cable entries and a 1/2 "NPT cable gland adapter
IP65
Pull wire ring
Thermoplastic head
Slow action contacts ( 2NC )
IMQ - cULus - CCC - CSA - EAC
LVD - 2014/35/EU
IEC 60947-5-1 / EN 60947-5-1
-25°C … +70°C
-30°C … +80°C
DP2T98W20A
Reinforced thermoplastic
50
Two PG11 threaded cable entries and a 1/2 "NPT cable gland adapter
IP65
Pull wire ring
Thermoplastic head
Slow action contacts ( 2NO )
IMQ - cULus - CCC - CSA - EAC
LVD - 2014/35/EU
IEC 60947-5-1 / EN 60947-5-1
-25°C … +70°C
-30°C … +80°C
DP2T98X11A
Reinforced thermoplastic
50
Two PG11 threaded cable entries and a 1/2 "NPT cable gland adapter
IP65
Pull wire ring
Thermoplastic head
Non-overlapping slow action contacts ( 1NO + 1NC )
IMQ - cULus - CCC - CSA - EAC
LVD - 2014/35/EU
IEC 60947-5-1 / EN 60947-5-1
-25°C … +70°C
-30°C … +80°C
DP2T98Y11A
Reinforced thermoplastic
50
Two PG11 threaded cable entries and a 1/2 "NPT cable gland adapter
IP65
Pull wire ring
Thermoplastic head
Overlapping slow action contacts (1NO + 1NC)
IMQ - cULus - CCC - CSA - EAC
LVD - 2014/35/EU
IEC 60947-5-1 / EN 60947-5-1
-25°C … +70°C
-30°C … +80°C
DP2T98Z11A
Reinforced thermoplastic
50
Two PG11 threaded cable entries and a 1/2 "NPT cable gland adapter
IP65
Pull wire ring
Thermoplastic head
Snap action contacts (1NO + 1NC)
IMQ - cULus - CCC - CSA - EAC
LVD - 2014/35/EU
IEC 60947-5-1 / EN 60947-5-1
-25°C … +70°C
-30°C … +80°C
DP3T9840W02A
Reinforced thermoplastic
50
Two cable inlets for PG11 cable glands
IP65
Pull wire ring
Thermoplastic head
Slow action contacts ( 2NC )
IMQ - cULus - CCC - CSA - EAC
LVD - 2014/35/EU
IEC 60947-5-1 / EN 60947-5-1
-40°C … +70°C
-40°C … +80°C
DP3T9840W20A
Reinforced thermoplastic
50
Two cable inlets for PG11 cable glands
IP65
Pull wire ring
Thermoplastic head
Slow action contacts ( 2NO )
IMQ - cULus - CCC - CSA - EAC
LVD - 2014/35/EU
IEC 60947-5-1 / EN 60947-5-1
-40°C … +70°C
-40°C … +80°C
DP3T9840X11A
Reinforced thermoplastic
50
Two cable inlets for PG11 cable glands
IP65
Pull wire ring
Thermoplastic head
Non-overlapping slow action contacts ( 1NO + 1NC )
IMQ - cULus - CCC - CSA - EAC
LVD - 2014/35/EU
IEC 60947-5-1 / EN 60947-5-1
-40°C … +70°C
-40°C … +80°C
DP3T9840Y11A
Reinforced thermoplastic
50
Two cable inlets for PG11 cable glands
IP65
Pull wire ring
Thermoplastic head
Overlapping slow action contacts (1NO + 1NC)
IMQ - cULus - CCC - CSA - EAC
LVD - 2014/35/EU
IEC 60947-5-1 / EN 60947-5-1
-40°C … +70°C
-40°C … +80°C
DP3T9840Z11A
Reinforced thermoplastic
50
Two cable inlets for PG11 cable glands
IP65
Pull wire ring
Thermoplastic head
Snap action contacts (1NO + 1NC)
IMQ - cULus - CCC - CSA - EAC
LVD - 2014/35/EU
IEC 60947-5-1 / EN 60947-5-1
-40°C … +70°C
-40°C … +80°C
DP3T98W02A
Reinforced thermoplastic
50
Two cable inlets for PG11 cable glands
IP65
Pull wire ring
Thermoplastic head
Slow action contacts ( 2NC )
IMQ - cULus - CCC - CSA - EAC
LVD - 2014/35/EU
IEC 60947-5-1 / EN 60947-5-1
-25°C … +70°C
-30°C … +80°C
DP3T98W20A
Reinforced thermoplastic
50
Two cable inlets for PG11 cable glands
IP65
Pull wire ring
Thermoplastic head
Slow action contacts ( 2NO )
IMQ - cULus - CCC - CSA - EAC
LVD - 2014/35/EU
IEC 60947-5-1 / EN 60947-5-1
-25°C … +70°C
-30°C … +80°C
DP3T98X11A
Reinforced thermoplastic
50
Two cable inlets for PG11 cable glands
IP65
Pull wire ring
Thermoplastic head
Non-overlapping slow action contacts ( 1NO + 1NC )
IMQ - cULus - CCC - CSA - EAC
LVD - 2014/35/EU
IEC 60947-5-1 / EN 60947-5-1
-25°C … +70°C
-30°C … +80°C
DP3T98Y11A
Reinforced thermoplastic
50
Two cable inlets for PG11 cable glands
IP65
Pull wire ring
Thermoplastic head
Overlapping slow action contacts (1NO + 1NC)
IMQ - cULus - CCC - CSA - EAC
LVD - 2014/35/EU
IEC 60947-5-1 / EN 60947-5-1
-25°C … +70°C
-30°C … +80°C
DP3T98Z11A
Reinforced thermoplastic
50
Two cable inlets for PG11 cable glands
IP65
Pull wire ring
Thermoplastic head
Snap action contacts (1NO + 1NC)
IMQ - cULus - CCC - CSA - EAC
LVD - 2014/35/EU
IEC 60947-5-1 / EN 60947-5-1
-25°C … +70°C
-30°C … +80°C
DP4T9840W02A
Reinforced thermoplastic
50
Two cable inlets for M16x1.5 cable glands
IP65
Pull wire ring
Thermoplastic head
Slow action contacts ( 2NC )
IMQ - cULus - CCC - CSA - EAC
LVD - 2014/35/EU
IEC 60947-5-1 / EN 60947-5-1
-40°C … +70°C
-40°C … +80°C
DP4T9840W20A
Reinforced thermoplastic
50
Two cable inlets for M16x1.5 cable glands
IP65
Pull wire ring
Thermoplastic head
Slow action contacts ( 2NO )
IMQ - cULus - CCC - CSA - EAC
LVD - 2014/35/EU
IEC 60947-5-1 / EN 60947-5-1
-40°C … +70°C
-40°C … +80°C
DP4T9840X11A
Reinforced thermoplastic
50
Two cable inlets for M16x1.5 cable glands
IP65
Pull wire ring
Thermoplastic head
Non-overlapping slow action contacts ( 1NO + 1NC )
IMQ - cULus - CCC - CSA - EAC
LVD - 2014/35/EU
IEC 60947-5-1 / EN 60947-5-1
-40°C … +70°C
-40°C … +80°C
显示压缩表示形式 (50 Produkt)