Create a simple sketch to find similar parts
Create a simple sketch to find similar parts
订购编码 | 2905142 |
Shorttext | Hybrid motor starter |
Longtext | Networkable hybrid motor starter for starting 3~ AC motors up to 500 V AC, output current: 3 A, emergency stop function, adjustable overload shutdown, and Push-in connection, DIN rail connector provided. |
上次修改 | 24.01.2025 18:32:39 |
单位 |
Description long | Networkable hybrid motor starter for starting 3~ AC motors up to 500 V AC, output current: 3 A, emergency stop function, adjustable overload shutdown, and Push-in connection, DIN rail connector provided. |
Description short | Hybrid motor starter |
GTIN-Code | 4046356920476 |
Order Number | 2905142 |
适合用于安装在标准导轨上 | Yes |
绝缘功能 | No |
协调类型 | 1 |
材料声明 | No |
产品类型 | ELR H3-IES-PT/500AC-3-IFS |
EAN代码 | 4046356920476 |
厂商产品编号 | 2905142 |
制造商名称 | Phoenix Contact GmbH & Co. KG |
使用规范 | IEC 60947-1, EN 60947-4-2, IEC 61508, ISO 13849 |
附加链接地址 | http://www.phoenixcontact.com/product/2905142 |
功率损耗规格的额定电流 [In] | 3 |
每极功率损耗,取决于电流 [PlIp] | 2.500 |
制造商产品说明 | Networkable hybrid motor starter for starting 3~ AC motors up to 500 V AC, output current: 3 A, emergency stop function, adjustable overload shutdown, and Push-in connection, DIN rail connector provided. |
制造商产品名称 | Hybrid motor starter |
制造商通用标识号 | 4063151 |
通信协议 | manufacturer-specific |
损耗功率 | 4.100 |
通过认证 | ATEX |
功能 | electronic switch |
总线功能 | Yes |
电气联接的设计(用于辅助/控制电流电路) | Spring pulley connection |
释放等级 | CLASS 10 |
额定工作电流Ie | 3 |
额定工作电流Ie(AC-3,400V) | 3 |
最大值-过载解扣调整范围 | 3 |
适合用于安装在标准导轨上 | Yes |
短路释放(是/否) | No |
最小额定控制电压Us(直流) | 19.200 |
绝缘功能 | No |
最小设定范围-过载释放触发器 | 0.180 |
type of coordination | 1 |
supported protocol | other bus systems |
material declaration | No |
Product type | ELR H3-IES-PT/500AC-3-IFS |
EAN代码 | 4046356920476 |
厂商产品编号 | 2905142 |
制造商名称 | Phoenix Contact GmbH & Co. KG |
辅助接点开启数量 | 0 |
辅助接点开关数量 | 0 |
控制点数量 | 0 |
使用规范 | IEC 60947-1, EN 60947-4-2, IEC 61508, ISO 13849 |
address of additional link | http://www.phoenixcontact.com/product/2905142 |
Kind of motor starter | Direct starter |
Temperature compensated overload protection | No |
Rated current [In] for the power loss specification | 3 |
Power loss per pole, current-dependent [PlIp] | 2.500 |
Manufacturer product description | Networkable hybrid motor starter for starting 3~ AC motors up to 500 V AC, output current: 3 A, emergency stop function, adjustable overload shutdown, and Push-in connection, DIN rail connector provided. |
Manufacturer product designation | Hybrid motor starter |
GLN of manufacturer | 4063151 |
高度 | 107.406675 |
通信协议 | manufacturer-specific |
损耗功率 | 4.100 |
通过认证 | ATEX |
深度 | 114 |
操纵方法 | DC |
连接说明 | Spring pulley connection |
功能 | electronic switch |
可装配承重轨 | Yes |
可以外部复位 | Yes |
总线功能 | Yes |
适用于“紧急关闭” | Yes |
宽度 | 22.6 |
保护方式IP | IP20 |
Type of electrical connection for auxiliary- and control current circuit | Spring pulley connection |
Release class | CLASS 10 |
Rated operation current Ie | 3 |
Rated operation current at AC-3, 400 V | 3 |
Overload release current setting | 3 |
With short-circuit release | No |
Rated control supply voltage DC | 19.200 |
Supporting protocol for Modbus | other bus systems |
Supporting protocol for AS-Interface Safety at Work | other bus systems |
Supporting protocol for PROFINET CBA | other bus systems |
Supporting protocol for Foundation Fieldbus | other bus systems |
Supporting protocol for EtherNet/IP | other bus systems |
Supporting protocol for DeviceNet Safety | other bus systems |
Supporting protocol for SERCOS | other bus systems |
Supporting protocol for PROFIsafe | other bus systems |
Supporting protocol for INTERBUS-Safety | other bus systems |
Supporting protocol for PROFINET IO | other bus systems |
Supporting protocol for SafetyBUS p | other bus systems |
Supporting protocol for PROFIBUS | other bus systems |
Supporting protocol for INTERBUS | other bus systems |
Supporting protocol for TCP/IP | other bus systems |
Supporting protocol for ASI | other bus systems |
Supporting protocol for DeviceNet | other bus systems |
Supporting protocol for SUCONET | other bus systems |
Supporting protocol for Data-Highway | other bus systems |
Supporting protocol for other bus systems | other bus systems |
Supporting protocol for LON | other bus systems |
Supporting protocol for CAN | other bus systems |
Number of auxiliary contacts as normally closed contact | 0 |
Number of auxiliary contacts as normally open contact | 0 |
Number of command positions | 0 |
Type of motor starter | Direct starter |
Temperature compensated overload protection | No |
Height | 107.406675 |
Depth | 114 |
Voltage type for actuating | DC |
Type of electrical connection of main circuit | Spring pulley connection |
Rail mounting possible | Yes |
External reset possible | Yes |
Suitable for emergency stop | Yes |
Width | 22.6 |
Degree of protection (IP) | IP20 |
Type of electrical connection for auxiliary- and control current circuit | Spring pulley connection |
Release class | CLASS 10 |
Rated operation current Ie | 3 |
Rated operation current at AC-3, 400 V | 3 |
Overload release current setting | 3 |
With short-circuit release | No |
Rated control supply voltage DC | 19.200 |
Supporting protocol for Modbus | other bus systems |
Supporting protocol for AS-Interface Safety at Work | other bus systems |
Supporting protocol for PROFINET CBA | other bus systems |
Supporting protocol for Foundation Fieldbus | other bus systems |
Supporting protocol for EtherNet/IP | other bus systems |
Supporting protocol for DeviceNet Safety | other bus systems |
Supporting protocol for SERCOS | other bus systems |
Supporting protocol for PROFIsafe | other bus systems |
Supporting protocol for INTERBUS-Safety | other bus systems |
Supporting protocol for PROFINET IO | other bus systems |
Supporting protocol for SafetyBUS p | other bus systems |
Supporting protocol for PROFIBUS | other bus systems |
Supporting protocol for INTERBUS | other bus systems |
Supporting protocol for TCP/IP | other bus systems |
Supporting protocol for ASI | other bus systems |
Supporting protocol for DeviceNet | other bus systems |
Supporting protocol for SUCONET | other bus systems |
Supporting protocol for Data-Highway | other bus systems |
Supporting protocol for other bus systems | other bus systems |
Supporting protocol for LON | other bus systems |
Supporting protocol for CAN | other bus systems |
Number of auxiliary contacts as normally closed contact | 0 |
Number of auxiliary contacts as normally open contact | 0 |
Number of command positions | 0 |
Type of motor starter | Direct starter |
Temperature compensated overload protection | No |
Height | 107.406675 |
Depth | 114 |
Voltage type for actuating | DC |
Type of electrical connection of main circuit | Spring pulley connection |
Rail mounting possible | Yes |
External reset possible | Yes |
Suitable for emergency stop | Yes |
Width | 22.6 |
Degree of protection (IP) | IP20 |